EA2 SERIES
PRODUCT LINEUP
Non-latch Type
at 20˚C
Nom inal Coil
Voltage
Coil
Must Operate
Voltage
Must Release
Voltage
Resistance
(Ω) ±10 %
(Vdc)
(Vdc)
(Vdc)
3
4.5
5
64.3
145
2.25
3.38
3.75
4.5
0.3
0.45
0.5
0.6
0.9
1.2
2.4
178
6
257
9
579
6.75
9
12
24
1028
2880
18
Single-Coil Latch Type
at 20˚C
Nom inal Coil
Voltage
Coil
Must Operate
Voltage
Must Release
Voltage
Resistance
(Ω) ±10 %
(Vdc)
(Vdc)
(Vdc)
3
4.5
5
90
202.5
250
2.25
3.38
3.75
4.5
2.25
3.38
3.75
4.5
6
360
9
810
6.75
9
6.75
9
12
24
1440
3840
18
18
Double-Coil Latch Type
(Can not be driven by revese polarity for reverse operation.)
at 20˚C
Nom inal Coil
Voltage
Coil
Must Operate
Voltage
Must Release
Voltage
Resistance
(Ω) ±10 %
(Vdc)
(Vdc)
(Vdc)
S
R
S
R
S
R
S
R
S
R
S
R
S
R
64.3
64.3
2.25
–
2.25
–
3
4.5
5
–
3.38
–
145
145
178
178
257
257
579
579
3.38
–
3.75
–
3.75
–
4.5
–
6
4.5
–
6.75
–
9
6.75
–
1028
1028
2880
2880
9
12
24
–
9
18
–
–
18
Note
Test by pulse voltage
–
S : Set coil (pin No.1... , pin No.5... ) R: Reset coil (pin No.10... , pin No.6... )
+
–
+
The latch type relays should be initalized at appointed position before using, and should be enegized to specific
polanity by a bone polabity to avoid wrong operation.
Any special coil requirem ent, please contact NEC for availability.
4
DATA SHEET ER0001EJ6V0DS00