EA2 SERIES
GUIDE TO APPLICATIONS
1. When connecting coils, refer to the pin configuration to prevent m isoperation or m alfunction.
2. The latch type relay should be initialized at the appointed position (set or reset position) when using, and should
be energized or deenergized to the specified polarity to avoid wrong operations by reversed contact state.
3. Soldering should be done at 250˚C within 10 sec.
4. Ultrasonic cleaning is not recom m ended to keep reliable contact perform ance. Alcohol-based solvents are
available as proper solvents.
5. Pressurized stress on the relay cover is not favorable to keep reliable operation of the relay during operation.
6. Minim um contact load of the relay is 10 m V, 10 µA.
This value is a reference value in the resistance load.
Minim um capacity changes depending on swiching frequency and environm ent tem perature and the load.
DATA SHEET ER0001EJ6V0DS00
7