Power Derating Curve
100
80
Natural
convection
100LFM
200LFM
60
40
400LFM
20
0
~
-40
0
20
40
60
80
100
110
Ambient Temperature
]
Notes
1
2
3
4
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
Ripple & Noise measurement bandwidth is 0-20 MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will
not damage these modules; however, they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
Specifications subject to change without notice.
5
6
Mechancial Drawing
Mechanical Dimensions
Pin Connections
Pin
1
Single Output
-Vin
Dual Output
-Vin
7
NC
NC
8
NC
Common
+Vout
-Vout
9
+Vout
-Vout
+Vin
10
16
+Vin
0.50 [0.02]
NC: No Connection
1
7
8
9
Bottom View
16
10
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
3.0
[0.12]
15.24 [0.60]
23.8 [0.94]
2.54
[0.10]
►Pin diameter ⇔ 0.5 ±0.05 (0.02±0.002)
Physical Outline
Case Size
Case Material
Weight
:
:
:
23.8x13.7x8.0mm(0.94x0.54x0.31 )inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
5.1g
DS_DB02S/D_03152012
E-mail: DCDC@delta.com.tw
http://www.delta.com.tw/dcdc