M C C
DL4614 thru DL4125
TM
Micro Commercial Components
ELECTRICAL CHARACTERISTICS (TA = 25ºC unless otherwise noted, VF = 1.1 V Max @ IF = 200mA for all types)
(3)
Zener Voltage (2)
Zener Ipedance (5)
ReverseLeakage Current (4)
Maximum
Zener
(IZM)
Device (1)
@IZT
ZZT
IR@VR
@IZT=250UA
Current
VZ (Volts)
Min
1.71
1.90
Nom
1.8
Max
1.89
2.10
mA
120
110
100
Volts
ohm(Max)
1200
µA( Max)
7.5
DL4614
1
1
1
1
2.0
5.0
1250
DL4615
DL4616
DL4617
DL4618
DL4619
DL4620
DL4621
DL4622
DL4623
4.0
2.31
-----
2.09
2.28
2.565
2.2
1300
1400
1500
1600
2.0
2.52
2.4
2.7
95
90
87
85
83
2.835
1
1
1.0
0.8
3.0
3.3
3.6
3.15
2.85
3.135
3.42
7.5
1.5
1650
1700
3.465
3.78
7.5
2
80
5.0
1650
2
2
4.095
4.515
3.705
4.085
3.9
4.3
4.0
77
75
1600
1550
3
3
4
10.0
10.0
10.0
4.465
4.845
5.32
4.7
5.1
5.6
6.2
6.8
DL4624
DL4625
DL4626
DL4627
4.935
5.355
5.88
70
1500
1400
1200
200
-
65
61
5.89
6.51
5
10.0
10.0
10.0
1.0
56
51
46
6.46
5.17
5.70
6.24
6.61
DL4099
DL4100
DL4101
DL4102
7.14
7.875
8.61
7.125
200
7.5
8.2
8.7
9.1
7.79
200
200
8.265
9.135
9.555
1.0
1.0
1.0
44
42
8.645
9.5
6.92
200
200
DL4103
DL4104
10
7.60
38
35
32
29
27
25
24
22
21
20
19
17
16
15
14
14
13
12
11
9.8
8.9
8.1
10.5
8.44
8.12
.05
.05
.05
.05
.05
.05
.05
.05
.05
.01
.01
.01
.01
.01
.01
.01
.01
.01
.01
.01
.01
200
200
200
200
100
100
100
100
150
150
150
150
150
150
200
200
200
200
200
250
250
DL4105
DL4106
10.45
11.4
12.35
13.3
14.25
15.2
16.15
17.1
18.05
19
11
12
13
14
15
11.55
12.6
13.65
14.7
15.75
16.8
17.85
18.9
19.95
21
23.1
25.2
26.25
28.35
29.4
31.5
34.65
37.8
40.95
45.15
49.35
9.857
10.65
11.40
12.15
12.92
13.67
14.44
15.20
16.72
18.25
19.00
20.45
21.28
22.80
DL4107
DL4108
DL4109
DL4110
DL4111
DL4112
DL4113
DL4114
DL4115
DL4116
DL4117
DL4118
DL4119
DL4120
DL4121
DL4122
DL4123
16
17
18
19
20
22
24
25
27
28
30
33
36
39
20.9
22.8
23.75
25.65
26.6
28.5
31.35
34.2
37.05
40.85
44.65
25.08
27.38
29.65
32.65
35.75
DL4124
DL4125
43
47
1. TOLERANCE AND TYPE NUMBER DESIGNATION (VZ)
The type numbers listed have a standard tolerance on the nominal zener voltage of 5%.
NOTES:
Nominal zener voltage is measured with the device junction in the thermal equilibrium
2. ZENER VOLTAGE (VZ) MEASUREMENT
at the lead temperature (TL) at 30°C
.
1°C and 3/8” lead length.
3. MAXIMUM ZENER CURRENT RATINGS (IZM
)
This data was calculated using nominal voltages. The maximum handing current
capability on a worst case basis is limited by the actual zener voltage at the opertation piont and the power derating curve.
.
4.Reverse Leakage Current(IR)reverse leakage current are guaranteed and measured at VR shown on the table .
5. Zener Impedance(ZZT) DerivationThe Zener impedance is derived from the 60 cycle ac voltage.which results when an Ac
.
current having an rms value to 10% of the DC zener current (IZT) is superimposed on IZT.
www.mccsemi.com
Revision: B
2012/08/03
2 of 5