DFEC40
OUTPUT SPECIFICATIONS
Parameter
Voltage accuracy
Conditions
Min.
-2.0
-1.5
-2.0
-5.0
-0.5
-1.0
-5.0
Typ.
Max.
+2.0
+1.5
+2.0
+5.0
+0.5
+1.0
+5.0
Unit
%
3.3Vout
Single / Dual
Triple: 3.3Vout, 5Vout
Triple: 12Vout, 15Vout
Line regulation
Load regulation
Low Line to High Line at Full Load
Single / Dual
%
%
Triple: 3.3Vout, 5Vout
Triple: 12Vout, 15Vout
3.3Vout
Min. Load to Full Load
-2.0
-1.5
-2.5
-5.0
+2.0
+1.5
+2.5
+5.0
Single / Dual
Triple: Main output: :(3.3Vout, 5Vout) 10% to
100% with 10% to 100% balanced onauxiliaries.
Auxiliary outputs 10% to 100% balanced on all
outputs.
Triple: 3.3Vout, 5Vout
Triple: 12Vout, 15Vout
Cross regulation
Dual: Asymmetrical load 25%/100% FL
Dual
Triple: Main output:(3.3Vout, 5Vout) 100% load, Triple: 3.3Vout, 5Vout
-5.0
-2.5
-5.0
+5.0
+2.5
+5.0
Triple: 12Vout, 15Vout
auxiliary 100%, other auxiliary 25% to 100%
load or main output:(3.3Vout, 5Vout) 25%,
auxiliary 25%, other auxiliary 25% to 100%.
Single output
%
%
Voltage adjustability
Ripple and noise
-3
-10
+17
+10
28Vout
Others
Single / Triple: Main
Single / Triple: Auxiliary
Single
Measured by
20MHz bandwidth
3.3Vout, 5Vout
12Vout, 15Vout
24Vout, 28Vout
12Vout
50
75
350
120
150
mVp-p
Dual
15Vou
Temperature coefficient
Transient response recovery
time
-0.02
+0.02
%/
25% load step change
Zener diode clamp
250
µs
Over voltage protection
3.3Vout
5Vout
3.9
6.2
15
18
30
36
12Vout
15Vout
24Vout
28Vout
VDC
Output indicator
Green LED
150
Over load protection
Short circuit protection
% of Iout rated; Hiccup mode
%
Continuous, automatics recovery
GENERAL SPECIFICATIONS
Parameter
Conditions
Min.
1600
1600
1
Typ.
Max.
Unit
Isolation voltage
1 minute
Input to Output
Input (Output) to Chassis
VDC
Isolation resistance
Isolation capacitance
Switching frequency
Safety meets
500VDC
GΩ
pF
4000
330
270
300
kHz
UL60950-1
EN60950-1
IEC60950-1
Aluminum
Chassis material
Weight
182g (6.40oz)
8.080 x 105 hrs
MTBF
MIL-HDBK-217F, Full load
ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature
Conditions
Min.
-40
Typ.
Max.
+58
+86
Unit
Without derating
With derating
+58
-40
Storage temperature range
Thermal shock
+105
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
Vibration
Relative humidity
www.PDUKE.com
3