Snap Action Switch

D2F-01-T 技术参数

是否无铅:不含铅是否Rohs认证:符合
生命周期:Active包装说明:ROHS COMPLIANT
Reach Compliance Code:unknownECCN代码:EAR99
HTS代码:8536.50.70.00风险等级:5.74
Is Samacsys:N执行器行程:0.75 mm
执行器类型:PIN PLUNGER主体宽度:5.8 mm
主体高度:6.5 mm主体长度或直径:12.8 mm
最大触点电流(直流):0.1 A触点(直流)最大额定R负载:.1A@30VDC
最大触点电压(直流):30 V电气寿命:30000 Cycle(s)
安装特点:THROUGH HOLE-STRAIGHT最大操作力:1.47 N
最高工作温度:65 °C最低工作温度:-25 °C
最大预行程:0.5 mm密封:IP40
表面贴装:NO开关动作:MOMENTARY
开关功能:SPDT开关类型:SNAP ACTING/LIMIT SWITCH
端接类型:SOLDERBase Number Matches:1

D2F-01-T 数据手册

 浏览型号D2F-01-T的Datasheet PDF文件第2页浏览型号D2F-01-T的Datasheet PDF文件第3页浏览型号D2F-01-T的Datasheet PDF文件第4页浏览型号D2F-01-T的Datasheet PDF文件第5页浏览型号D2F-01-T的Datasheet PDF文件第7页浏览型号D2F-01-T的Datasheet PDF文件第8页 
Precautions  
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,  
“Snap Action Switches, Technical Information” for correct use.  
Correct Use  
Cautions  
Mounting  
Terminal Connection  
Turn OFF the power supply before mounting or removing the switch,  
wiring the switch, or performing maintenance or inspection. Failure to  
do so may result in electric shock or burning.  
When soldering a lead wire to the terminal, first insert the lead wire  
conductor into the terminal hole and then perform soldering.  
Make sure that the capacity of the soldering iron is 30 W maximum  
and that the temperature of the soldering tip is approximately 300 °C.  
(350 °C maximum.) Complete soldering within 3 s. After soldering,  
do not apply external force to the soldered area for about 1 minute.  
Mount the switch onto a flat surface. Mounting on an uneven surface  
may cause deformation of the switch, resulting in faulty operation or  
breakage of the housing.  
Allow sufficient insulation distance between terminals, terminal  
traces and between terminals and ground.  
Using a switch with improper soldering may result in abnormal heat-  
ing, possibly resulting in a burn.  
Applying the soldering iron for more than 3 s or using an iron that is  
rated for more than 30 W may deteriorate the switch characteristics.  
Operating Stroke Setting  
Take particular care in setting the operating stroke for the pin plunger  
models. Make sure that the operating stroke is 70% to 100% of the  
rated OT distance. Do not operate the actuator exceeding the OT  
distance, otherwise the service life of the switch maybe decreased.  
When soldering the lead wire to the PCB terminal, pay careful  
attention so that the flux and solder liquid level does not exceed the  
PCB level.  
Using Microloads  
Using a model for ordinary loads to switch microloads may result in  
faulty operation. Instead, use the models that are designed for micro-  
loads and that operate in the following range;  
Operating  
range for  
general-load  
models  
Operating range  
for micro load  
models D2F-01  
D2F  
Inoperable  
range  
Current (mA)  
However, even when using microload models within the operating  
range shown above, if inrush current or inductive voltage spikes  
occur when the contact is opened or closed, it may increase contact  
wear and so decrease the service life. Therefore, insert a contact  
protection circuit where necessary.  
36  
Snap Action Switch D2F  

与D2F-01-T相关器件

型号 品牌 描述 获取价格 数据表
D2F20 SHINDENGEN General Purpose Rectifiers(200V 1.4A)

获取价格

D2F-5 OMRON Ultra Subminiature Basic Switches (J-Size)

获取价格

D2F-5L OMRON Ultra Subminiature Basic Switches (J-Size)

获取价格

D2F-5L3 OMRON Ultra Subminiature Basic Switches (J-Size)

获取价格

D2F60 SHINDENGEN General Purpose Rectifiers(600V 1.4A)

获取价格

D2F-A OMRON Snap Action Switch

获取价格