CR22™ 2' x 2' Architectural LED Troffer with Cree SmartCast® Technology
Photometry
CR22-32L-30K BASED ON CSA REPORT TEST #: 2362893-01
Luminaire photometry has been conducted by a NVLAP accredited testing laboratory in accordance with IESNA LM-79-08. IESNA LM-79-08 specifies the entire luminaire as the source
resulting in a luminaire efficiency of 100%.
90˚
Average Luminance Table (cd/m2)
0
291
582
Coefficients Of Utilization –
Zonal Cavity Method
Zonal Lumen Summary
Horizontal Angle
Zone
0-30
0-40
0-60
0-90
0-180
Lumens
925
% Lamp
N/A
Luminaire
28.2%
46.7%
82.7%
100%
RC %:
80
70
119
110
100
91
70˚
50˚
0°
45°
90°
RW %:
50
119
105
92
81
72
64
58
52
48
44
40
30
119
101
86
73
63
55
49
44
39
36
32
10
119
98
80
67
57
49
43
38
33
30
27
45°
55°
65°
75°
85°
3,517
3,117
2,439
1,559
359
3,799
3,552
2,970
2,063
203
3,852
3,568
3,066
1,656
133
1,532
2,716
3,284
3,284
N/A
RCR: 0
N/A
1
2
3
4
5
6
7
8
9
10
N/A
N/A
100%
873
84
77
Reference www.cree.com/Lighting/Products/Indoor/Troffers/CR-Series for detailed photometric data
1164
71
0˚
20˚
0˚
90˚
66
61
57
53
Effective Floor Cavity Reflectance: 20%
Application Reference
Based on CR22-32L-30K Luminaire
Recommended CR Series Lumen Maintenance Factors (LMF)1
Open Space
25K hr
Projected2
LMF
50K hr
Projected2
LMF
75K hr
100K hr
Calculated3
LMF
Spacing
8 x 8
Lumens
3,200
Wattage
32W
LPW
100
w/ft2
0.55
0.44
0.35
0.29
Average fc
Initial
LMF
Ambient
Calculated3
LMF
44
37
31
25
8 x 10
1.05
1.04
1.03
1.02
1.01
1.00
0.99
0.98
0.97
1.04
1.03
1.02
1.01
1.00
0.99
0.98
0.97
0.96
1.04
1.03
1.02
1.01
1.00
0.99
0.98
0.97
0.96
1.04
1.03
1.02
1.01
1.00
0.99
0.98
0.97
0.96
1.04
1.03
1.02
1.01
1.00
0.99
0.98
0.97
0.96
0˚C (32˚F)
10 x 10
10 x 12
5˚C (41˚F)
9' ceiling: 80/50/20 reflectances; 2.5' workplane, open room. LLF: 1.0 Initial Open Space: 50' x 40' x 10'
10˚C (50˚F)
15˚C (59˚F)
20˚C (68˚F)
25˚C (77˚F)
30˚C (86˚F)
35˚C (95˚F)
40˚C (104˚F)
1 Lumen maintenance values at 25˚C are calculated per TM-21 based on LM-80 data and in-situ luminaire testing
2 In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times
(6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)
3 In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA LM-80-08 total
test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)
© 2016 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change.
Patent www.cree.com/patents. Cree®, SmartCast®, the SmartCast logo, TrueWhite®, and Cree TrueWhite® are registered trademarks,
and CR22™, the Cree logo, the Cree TrueWhite Technology logo, and OneButton™ are trademarks of Cree, Inc. The UL logo is a
registered trademark of UL LLC. The DLC QPL logo is a registered trademark of Northeast Energy Efficiency Partnerships, Inc.
US: lighting.cree.com/lighting
Canada: www.cree.com/canada
T (800) 236-6800 F (262) 504-5415
T (800) 473-1234 F (800) 890-7507