CPC1014N
INTEGRATED
CIRCUITS
DIVISION
Absolute Maximum Ratings @ 25ºC
Absolute Maximum Ratings are stress ratings. Stresses in
Parameter
Blocking Voltage
Ratings
60
Units
VP
excess of these ratings can cause permanent damage to the
device. Functional operation of the device at conditions beyond
those indicated in the operational sections of this data sheet is
not implied.
Reverse Input Voltage
5
50
V
Input Control Current
Peak (10ms)
mA
A
1
Input Power Dissipation 1
Total Power Dissipation 2
70
mW
mW
Vrms
°C
Typical values are characteristic of the device at +25°C, and
are the result of engineering evaluations. They are provided for
information purposes only, and are not part of the manufacturing
testing requirements.
400
Isolation Voltage, Input to Output
Operational Temperature, Ambient
Storage Temperature
1500
-40 to +85
-40 to +125
°C
1
2
Derate linearly 1.33 mW / ºC.
Derate output power linearly 3.33 mW / ºC.
Electrical Characteristics @ 25ºC
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics
Blocking Voltage
IL=1A
VDRM
60
-
-
V
Load Current
Continuous 1
IF=2mA
t <10ms
IL=400mA
VL=60VP
IL
-
-
-
-
-
-
-
-
400
1
mArms / mADC
Peak
On-Resistance 2
ILPK
RON
ILEAK
AP
2
Off-State Leakage Current
Switching Speeds
1
µA
Turn-On
ton
toff
-
-
-
0.47
0.22
25
2
1
-
IF=5mA, VL=10V
ms
pF
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate 3
Input Control Current to Deactivate
Input Voltage Drop
Reverse Input Current
Common Characteristics
Capacitance, Input to Output
IF=0mA, VL=50V, f=1MHz
COUT
IL=400mA
-
IF
IF
-
0.25
0.2
1.36
-
2
-
mA
mA
V
0.1
0.9
-
IF=5mA
VR=5V
VF
IR
1.5
10
µA
VIO=0V, f=1MHz
CIO
-
1
-
pF
1
2
3
Load current derates linearly from 400mA @ 25oC to 200mA @85oC.
Measurement taken within 1 second of on-time.
For applications requiring high temperature operation (greater than 60oC) a minimum LED drive current of 4mA is recommended.
2
R07
www.ixysic.com