CDM10V-2
Flexible 0-10V Dimming Solution
Electrical characteristics and parameters
4
Electrical characteristics and parameters
Table 3
Pin
Absolute Maximum Ratings
Name
Values
Unit
Note or Test
Condition
Min.
Max.
1
2
3
Vcc
11
0
25
0
V
V
V
GND
Iout
Point of reference
-0.5
3.63
Depending on the
optocupler voltage
@ 5mA
4
5
6
NC
-0.25
-0.25
-0.5
0.1
0.1
V
V
V
Connect to GND
during operation
NC
Connect to GND
during operation
Rdim+
VCC + 0.5
An applied voltage
above max value
leads to the
destruction of the
device. Also valid if
VCC is 0 V.
Absolute maximum ratings (Table 3) are defined as ratings which when being exceeded may lead to destruction
of the integrated circuit. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability. Maximum ratings are absolute ratings; exceeding only one of these values may cause
irreversible damage to the integrated circuit. These values are not tested during production test.
Table 4
Electrical Characteristics
Symbol
Parameter
Values
Typ.
Unit Note or Test
Condition
Min.
11
Max.
25
Input Voltage
Vin
TJ
V
Operating Voltage
Junction Temperature
Range
-40
135
°C
Ambient Temperature
Range
TA
-40
105
°C
Power Dissipation
Ptot
6.05 @ 1%
duty cycle;
130 @ 100% duty 160 @ mW
Dimmer current
included
cycle
100%
PWM &
25 Vin
54 @ 50% duty
cycle
Current Consumption
ICC
1
mA
Current
Consumption of
the IC for self
supply
Output Current for
Dimmer
Idim
Iout
-10%
-10%
-6%
200
5
+10%
+10%
+6%
μA
mA
Hz
Current flow out
of Rdim+-Pin
Output Current for
Optocoupler
PWM frequency
fPWM
1000
Datasheet
7
V1.1