Advanced
CAT24CXX1/XX2
A.C. CHARACTERISTICS
V
=2.7V to 6.0V unless otherwise specified.
CC
Output Load is 1 TTL Gate and 100pF
Read & Write Cycle Limits
Symbol
Parameter
VCC=2.7V - 6V
VCC=4.5V - 5.5V
Min.
Max.
100
Min.
Max.
Units
kHz
ns
FSCL
TI(1)
Clock Frequency
400
200
Noise Suppression Time
200
Constant at SCL, SDA Inputs
tAA
SCL Low to SDA Data Out
and ACK Out
3.5
1
µs
µs
(1)
tBUF
Time the Bus Must be Free Before
a New Transmission Can Start
4.7
1.2
tHD:STA
tLOW
Start Condition Hold Time
Clock Low Period
4
0.6
1.2
0.6
0.6
µs
µs
µs
µs
4.7
4
tHIGH
Clock High Period
tSU:STA
Start Condition Setup Time
4.7
(for a Repeated Start Condition)
tHD:DAT
tSU:DAT
Data In Hold Time
0
0
ns
ns
µs
ns
µs
ns
Data In Setup Time
50
50
(1)
tR
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
1
0.3
(1)
tF
300
300
tSU:STO
tDH
4
0.6
100
100
(1)(2)
Power-Up Timing
Symbol
Parameter
Max.
Units
ms
tPUR
tPUW
Power-up to Read Operation
Power-up to Write Operation
1
1
ms
Note:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
(2) t and t are the delays required from the time V is stable until the specified operation can be initiated.
PUR
PUW
CC
Write Cycle Limits
Symbol
Parameter
Min.
Typ.
Max
Units
tWR
Write Cycle Time
10
ms
The write cycle time is the time from a valid stop condition of a write sequence to the end of the internal program/erase
cycle. During the write cycle, the bus interface circuits are disabled, SDA is allowed to remain high, and the device
does not respond to its slave address.
Doc. No. 25079-00 1/98 M-1