Output filters
B84143V*R127
3-line sine-wave EMC output filters SineFormer
Typicalꢀcircuitꢀdiagram
Technical data and measuring conditions
Rated voltage VR
520 V AC
320 A filter: 600 V AC
Rated current IR
Test voltage Vtest
Referred to 40 °C rated temperature
2100 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Converter output frequency fM
Pulse frequency fP
0 Hz … 100 Hz
4 kHz ... 8 kHz (Type 320 A: 2.5 kHz ... 8 kHz)
At IR and 50 Hz
Voltage drop ∆U (input to output)
Power losses PL
At IR and 50 Hz
Overload capability (thermal)
Max. dv/dt on filter input
Convection distance to other devices
Vibration (sine)
1.5 ꢁ IR for 1 min per hour
5 kV/μs
see dimensional drawing "Convection space"
10 cycles, 1 oct./min,
3 Hz ... 13 Hz: 3 mm; 13 Hz ... 200 Hz: 1 g
(according to IEC 60068-2-6)
Shock (half sine)
15 g, 11 ms, 3 axis, 3 shocks per direction,
18 total (according to IEC 60068-2-6)
Temperature housing
approx. 70 °C
Noise level of filter
approx. 72 dB (A)
Climatic category (IEC 60068-1)
25/100/21 (ꢀ25 °C/+100 °C/21 days damp heat test)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 13