3-line filters
B84143B*R000
for converters and power electronics
Typical circuit diagram
Technical data and measuring conditions
Rated voltage VR
Rated current IR
Test voltage Vtest
250/440 V AC (50/60 Hz)
Referred to 40 °C rated temperature
1770 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Overload capability (thermal)
1.5 ꢁ IR for 3 min per hour or
2.5 ꢁ IR for 30 s per hour
Leakage current lLK
At VR and 50 Hz
Climatic category (IEC 60068-1)
25/100/21 (ꢀ25 °C/+100 °C/21 days damp heat test)
Characteristics and ordering codes
IR
Terminal cross section ILK
mm2
Rtyp
Approx. Ordering code
weight
kg
A
mA
mΩ
VR = 250/440 V AC
8
12
16
25
36
50
80
4
4
4
10
10
10
25
0.359
0.359
0.359
0.862
0.862
2.19
80
40
25
10
5.0
3.5
2.0
3.8
3.8
3.8
5.7
5.7
5.7
B84143B0008R000
B84143B0012R000
B84143B0016R000
B84143B0025R000
B84143B0036R000
B84143B0050R000
B84143B0080R000
2.98
16
For filters for higher currents see B84143B*R110.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 13