2-line filters
B84115E
SIFI-E for high insertion loss
Circuit diagram
LINE
L
LOAD
L’
N
N’
SSB0270-8
Technical data and measuring conditions
Rated voltage VR
Rated current IR
Test voltage Vtest
250 V DC/AC, 50/60 Hz
Referred to 40 °C ambient temperature
1414 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Leakage current lleak
Climatic category (IEC 60068-1)
Approvals
At 230 V AC, 50 Hz
25/085/21 (–25 °C/+85 °C/21 days damp heat test)
EN 133200, UL 1283, CSA C22.2 No.8
Characteristics and ordering codes
IR
CR
LR
Ileak Case Appr. Ordering code
style weight
Mounting plate
for top-hat rail
(ordering code)
A
mH
mA
g
VR = 250 V DC/AC, 50/60 Hz
3
0.47 µF (X2)
+
2 × 4.7 nF (Y2) 2 × 16
2 × 0.27 < 0.5 A
210
210
270
B84115E0000A030
B84115E0000B030 C62122A0132B092
B84115E0000K030
—
+
B
K
—
6
0.47 µF (X2)
+
2 × 22 nF (Y2) 2 × 4.7
2 × 0.10 < 3.5 A
510
510
510
B84115E0000A060
B84115E0000B060 C62122A0132B095
B84115E0000K060
—
+
B
K
—
10 0.47 µF (X2)
2 × 0.047 < 3.5 A
690
690
B84115E0000A110
B84115E0000B110 C62122A0132B095
—
+
+
B
2 × 22 nF (Y2) 2 × 3.6
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06