5秒后页面跳转
B84114D0000A110 PDF预览

B84114D0000A110

更新时间: 2024-01-18 18:34:54
品牌 Logo 应用领域
东电化 - TDK /
页数 文件大小 规格书
10页 421K
描述
1-phase(250V), Rated Current:10A

B84114D0000A110 数据手册

 浏览型号B84114D0000A110的Datasheet PDF文件第4页浏览型号B84114D0000A110的Datasheet PDF文件第5页浏览型号B84114D0000A110的Datasheet PDF文件第6页浏览型号B84114D0000A110的Datasheet PDF文件第8页浏览型号B84114D0000A110的Datasheet PDF文件第9页浏览型号B84114D0000A110的Datasheet PDF文件第10页 
2-line filters  
B84114D  
SIFI-D for high insertion loss  
The table below summarizes the safety instructions that must be observed without fail. A detailed  
description can be found in the relevant chapters of the databook.  
Topic  
Instructions  
Reference chapter  
(data book),  
paragraph  
Selecting a filter  
When selecting a filter, it is mandatory to observe the Selection guide for  
rated data of the equipment (such as its rated input  
current, rated voltage, harmonic content etc.) as well  
as the derating instructions in Chapters 9 and 10.  
converter filters  
Rated voltage  
When power distribution systems deviating from the  
Power distribution  
symmetric TN-S system it is to check the suitability of systems,  
the EMC filters and the allowed voltages including the  
fault cases.  
7
Protection from  
residual voltages  
Discharge resistors  
Active parts must be discharged within 5 s to a Safety regulations,  
voltage of less than 60 V (or 50 µ C). If this limit 6.1  
cannot be observed due to the operating mode, the  
hazardous point must be permanently marked in a  
clearly visible way.  
Filters which are not permanently connected (e.g.  
when the test voltage is applied to the filter at the  
incoming goods inspection) must be discharged after  
the voltage has been switched off.  
Safety regulations,  
6.2  
Installing and  
removing of EMC  
filters  
When installing and removing our EMC filters, a Safety regulations,  
voltage-free state must be set up and secured with 6.4  
observance of the five safety rules described in  
EN 50110-1.  
Installation  
Use in IT systems  
The special features of the IT system ("first fault case" Power distribution  
and other fault cases) shall be observed.  
system (network  
types), 7.6  
Safety notes on  
leakage currents  
The filter leakage currents specified in the data book Leakage current,  
are intended for user information only.The maximum 8.4  
leakage current of the entire electrical equipment or Leakage current,  
appliance has to be limited for safety reasons. Please 8.6  
obtain the applicable limits for your application from  
the relevant regulations, provisions and standards.  
Voltage derating  
If the permissible limits for the higher-frequency Voltage derating,  
voltages at the filter are exceeded, the filter may be 9.8  
damaged or destroyed.  
Hazards caused by  
overloading the filters  
Current derating at  
elevated ambient  
temperatures  
Non-observance of the current derating may lead to Current derating,  
overheating and consequently represents  
hazard.  
a fire 10.1  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 7 of 10  

与B84114D0000A110相关器件

型号 品牌 描述 获取价格 数据表
B84114D0000B010 EPCOS SIFI-D for high insertion loss

获取价格

B84114D0000B010 TDK 1-phase(250V), Rated Current:1A

获取价格

B84114D0000B020 EPCOS SIFI-D for high insertion loss

获取价格

B84114D0000B020 TDK Single Phase EMI Filter, 250V, 50/60HzHz,

获取价格

B84114D0000B030 EPCOS SIFI-D for high insertion loss

获取价格

B84114D0000B030 TDK 1-phase(250V), Rated Current:3A

获取价格