2-line filters
B84111F
SIFI-F for normal insertion loss
Characteristics and ordering codes
CR
X2
μF
CR
Y2
pF
Approvals
IR
LR
ILK
Approx. Ordering code
weight
g
A
mH
mA
VR = 250 V AC/DC
3
3
6
6
2 × 0.1
2 × 0.1
2 × 0.1
2 × 0.1
2 × 4700 2 × 1.5
2 × 1.5
2 × 4700 2 × 1.8
2 × 1.8
2 × 4700 2 × 0.87
2 × 0.87
2 × 4700 2 × 0.65
2 × 0.65
2 × 4700 2 × 0.43
2 × 0.43
2 × 4700 2 × 0.66
2 × 0.66
2 × 10000 2 × 0.4
2 × 0.4
0.369 90
90
0.369 90
90
0.369 90
90
0.369 130
130
0.369 130
130
0.369 300
300
0.785 300
300
B84111F0000B030
B84111F0000M030
B84111F0000B060
B84111F0000M060
B84111F0000B110
B84111F0000M110
B84111F0000B116
B84111F0000M116
B84111F0000B120
B84111F0000M120
B84111F0000G125
B84111F0000M125
B84111F0000G136
B84111F0000M136
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
ꢀ
0
ꢀ
0
10 2 × 0.1
10 2 × 0.1
16 2 × 0.1
16 2 × 0.1
20 2 × 0.1
20 2 × 0.1
25 2 × 0.1
25 2 × 0.1
36 2 × 0.47
36 2 × 0.47
ꢀ
0
ꢀ
0
ꢀ
0
ꢀ
0
ꢀ
0
× = Approval granted
Dimensional drawings
B84111F0000*030, B84111F0000*060, B84111F0000*110 (3 A, 6 A, 10 A)
General tolerances according to ISO 2768ꢀcL
Dimensions in mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 15