Pressure sensors Gauge pressure transducers

B58611K1100A003 技术参数

生命周期:ActiveReach Compliance Code:unknown
风险等级:5.78Is Samacsys:N
其他特性:SENSITIVITY IS 500 MV/BAR主体宽度:14 mm
主体高度:22.5 mm主体长度或直径:15 mm
外壳:STAINLESS STEEL安装特点:THROUGH HOLE MOUNT
标称偏移:0MV最高工作温度:85 °C
最低工作温度:-30 °C封装形状/形式:RECTANGULAR
端口类型:HOLE压力传感模式:GAGE
传感器/换能器类型:PRESSURE SENSOR,PEIZORESISTIVE最大供电电压:10 V
表面贴装:NO端接类型:SOLDER
Base Number Matches:1

B58611K1100A003 数据手册

 浏览型号B58611K1100A003的Datasheet PDF文件第1页浏览型号B58611K1100A003的Datasheet PDF文件第2页浏览型号B58611K1100A003的Datasheet PDF文件第3页浏览型号B58611K1100A003的Datasheet PDF文件第4页浏览型号B58611K1100A003的Datasheet PDF文件第5页浏览型号B58611K1100A003的Datasheet PDF文件第7页 
Pressure sensors  
Gauge pressure transducers  
AK2 series  
Cautions and warnings  
Storage (general)  
All pressure sensors should be stored in their original packaging. They should not be placed in harmful environments such  
as corrosive gases nor exposed to heat or direct sunlight, which may cause deformations. Similar effects may result from  
extreme storage temperatures and climatic conditions. Avoid storing the sensor dies in an environment where condensation  
may form or in a location exposed to corrosive gases, which will adversely affect their performance. Plastic materials should  
not be used for wrapping/packing when storing or transporting these dies, as they may become charged. Pressure sensor  
dies should be used soon after opening their seal and packaging.  
Operation (general)  
Media compatibility with the pressure sensors must be ensured to prevent their failure. The use of other media can cause  
damage and malfunction. Never use pressure sensors in atmospheres containing explosive liquids or gases.  
Ensure pressure equalization to the environment, if gauge pressure sensors are used. Avoid operating the pressure sensors  
in an environment where condensation may form or in a location exposed to corrosive gases. These environments adversely  
affect their performance.  
If the operating pressure is not within the rated pressure range, it may change the output characteristics. This may also  
happen with pressure sensor dies if an incorrect mounting method is used. Be sure that the applicable pressure does not  
exceed the overpressure, as it may damage the pressure sensor.  
Do not exceed the maximum rated supply voltage nor the rated storage temperature range, as it may damage the pressure  
sensor.  
Temperature variations in both the ambient conditions and the media (liquid or gas) can affect the accuracy of the output  
signal from the pressure sensors. Be sure to check the operating temperature range and thermal error specification of the  
pressure sensors to determine their suitability for the application.  
Connections must be wired in accordance with the terminal assignment specified in the data sheets. Care should be taken  
as reversed pin connections can damage the pressure transmitters or degrade their performance. Contact between the  
pressure sensor terminals and metals or other materials may cause errors in the output characteristics.  
Design notes (dies)  
This specification describes the mechanical, electrical and physical requirements of a piezoresistive sensor die for  
measuring pressure. The specified parameters are valid for the pressure sensor die with pressure application either to the  
front or back side of the diaphragm as described in the data sheet. Pressure application to the other side may result in  
differing data. Most of the parameters are influenced by assembly conditions. Hence these parameters and the reliability  
have to be specified for each specific application and tested over its temperature range by the customer.  
Handling/Mounting (dies)  
Pressure sensor dies should be handled appropriately and not be touched with bare hands. They should only be picked up  
manually by the sides using tweezers. Their top surface should never be touched with tweezers. Latex gloves should not be  
used for handling them, as this will inhibit the curing of the adhesive used to bond the die to the carrier. When handling, be  
careful to avoid cuts caused by the sharp-edged terminals. The sensor die must not be contaminated during manufacturing  
processes (gluing, soldering, silk-screen process).  
The package of pressure sensor dies should not to be opened until the die is mounted and should be closed after use. The  
sensor die must not be cleaned. The sensor die must not be damaged during the assembly process (especially scratches on  
the diaphragm).  
Soldering (transducers, transmitters)  
The thermal capacity of pressure sensors is normally low, so steps should be taken to minimize the effects of external heat.  
High temperatures may lead to damage or changes in characteristics.  
A non-corrosive type of flux resin should normally be used and complete removal of the flux is recommended.  
Avoid rapid cooling due to dipping in solvent. Note that the output signal may change if pressure is applied to the terminals  
during soldering.  
This listing does not claim to be complete, but merely reflects the experience of EPCOS AG.  
AS SEN PD  
2009-08-03  
Please read Cautions and warnings and  
Page 6 of 7  
Important notes at the end of this document.  

与B58611K1100A003相关器件

型号 品牌 描述 获取价格 数据表
B58611K1100A004 EPCOS Pressure sensors Gauge pressure transducers

获取价格

B58611K1100A004 TDK Peizoresistive Sensor, Gage, Rectangular, Through Hole Mount, HALOGEN FREE AND ROHS COMPLI

获取价格

B58611K1100A005 EPCOS Pressure sensors Gauge pressure transducers

获取价格

B58611K1100A005 TDK Peizoresistive Sensor, Gage, Rectangular, Through Hole Mount, HALOGEN FREE AND ROHS COMPLI

获取价格

B58611K1100A006 EPCOS Pressure sensors Gauge pressure transducers

获取价格

B58611K1100A006 TDK Peizoresistive Sensor, Gage, Rectangular, Through Hole Mount, HALOGEN FREE AND ROHS COMPLI

获取价格