VL (AZ8)
SPECIFICATIONS
1. Rating
1) Standard type
2) Types with neon lamp and with LED
Load
Resistive load
(cos φ]1)
Inductive load
(cos φ]0.4)
Resistive load
(cos φ]1)
Inductive load
(cos φ]0.4)
Rated control
voltage
Types
Rated control voltage
125V AC
250V AC
125V DC
5A
5A
3A
2A
125V AC
With Neon lamp
5A
5A
3A
3A
2A
–
240V AC
0.4A
0.1A
With LED
24V DC
2. Characteristics
Contact arrangement
Initial contact resistance, max.
Contact material
1 Form A 1 Form B
15mΩ (By voltage drop 6 to 8V DC at rated current)
Gold clad silver alloy (cadmium free)
Min. 100MΩ
Initial insulation resistance (At 500V DC)
1,000Vrms for 1 min Between non-consecutive terminals 2,000Vrms for 1 min Between
dead metal parts and each terminal 2,000Vrms for 1 min Between ground and each terminal
Initial breakdown voltage
In the free position
Max. 98m/s2 {10G}
Shock resistance max.
Vibration resistance
In the full operating position
Max. 294m/s2{30G}
Standard type: Max. 55Hz Type with indicator: 10 to 50Hz, double amplitude of 1.5mm
107 (at 120 cpm)
3ꢀ105 (at rated resistive load) 5ꢀ106 (Magnetic contactor FC-100 200V AC load)
Min. 2ꢀ104 hours (Neon lamp type)
Mechanical
Electrical
Expected life (Min. operations)
Life of lamp
Ambient temperature/Ambient humidity
Max. operating speed
–20 to +60°C –4 to +140°F/Max. 95%
120 cpm
3. EN60947-5-1 performance
Item
Rating
250VAC
2.5kV
2.5kV
5A
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp)
Switching overvoltage
Rated enclosed thermal current (Ithe)
Conditional short-circuit current
Short-circuit protection device
Protective construction
100A
10A fuse
IP64
Pollution degree
3
4. Operating characteristics
Characteristics
O.F. (N {gf}) max.
Actuator
Pretravel (P.T.), max. Movement Differential Overtravel (O.T.), min. Totaltravel (T.T.), min.
R.F. (N {gf}) min.
mm inch
(M.D.), max. mm inch
mm inch
mm inch
Push plunger
Roller plunger
8.83 {900}
5.88 {600}
1.47 {150}
0.49 {50}
1.5 .059
0.7 .028
4 .028
5.5 .217
Cross roller plunger
Roller arm
20°
20°
10°
10°
10°
–
75°
75°
95°
95°
Adjustable roller arm
Adjustable rod
7.84 {800}~3.35 {342} 0.49 {50}~0.21 {21}
7.84 {800}~1.99 {203} 0.49 {50}~0.12 {12}
20°
75°
95°
Flexible rod spring wire
0.88 {90}
–
30 (1.181)
20 (.787)
50 (1.969)
*Characteristics measured at bent condition: min. radius 100mm 3.937inch.
Notes) 1. Keep the total travel values in the specified range. Otherwise the actuator force may rise to several times the operating force, resulting in a mechanical failure or much shorter service life.
2. For the operating characteristics, refer to the TECHNICAL INFORMATION.
5. Protective construction
6.Lamp rating
Protective construction
Types
Rated operating voltage Operating voltage range
Internal resister
120kΩ
VL Mini limit switch
(with lamp)
VL Mini limit switch
IEC
IP60
IP64
Neon lamp
100 to 200V AC
6V DC
80 to 240V AC
5 to 15V DC
9 to 28V DC
20 to 55V DC
ꢀ
ꢀ
ꢀ
ꢀ
2.4kΩ
4.7kΩ
15kΩ
LED
12V DC
24 to 48V DC
DATA
WIRING DIAGRAM
1. Life curve
2. Actual load life curve (relay coil load)
Output circuit
VL
13
N.O.
11
14
12
,
Life curve resistive load
N.O.
N.C.
(
)
φ
AC 240VC cos =1
1000
1000
500
N.C.
500
Terminal
400
300
200
13
14
0
0.5 1.0
NK HC
3
5
50
260 700
HPHG VC-20 FC-10 FC-35 FC-100
Various relay loads VA
100
30
(
)
0
5
10
11
12
,
Load current
A
Note: The FC magnetic contactor series is 200V AC. The NK
is 2 Form C 24V DC type.
54