Table 5-3.
DC and operating characteristics for read operation
Symbol
Parameter
Condition
Min
Max
1.0
Units
A
A
A
mA
mA
V
ILI
Input load current
Output leakage current
VIN = 0V to VCC (Com., Ind.)
VOUT = 0V to VCC (Com., Ind.)
ISB1 (CMOS), CE = VCC 0.3V
ISB2 (TTL), CE = 2.0 to VCC + 0.5V
f = 5MHz, IOUT = 0mA, CE = VIL
ILO
5.0
100
1.0
ISB
VCC(1) standby current
ICC
VIL
VCC active current
Input low voltage
Input high voltage
Output low voltage
Output high voltage
40
-0.6
2.0
0.8
VIH
VCC + 0.5
0.4
V
VOL
VOH
Note:
IOL = 2.1mA
V
IOH = -400µA
2.4
V
1. VCC must be applied simultaneously or before OE/ VPP , and removed simultaneously or after OE/VPP
Table 5-4.
AC characteristics for read operation
Atmel AT27C080-90
Symbol
Parameter
Condition
Min
Max
Units
CE =OE/VPP
(4)
tACC
Address to output delay
90
ns
= VIL
(3)
tCE
CE to output delay
OE to output delay
OE = VIL
CE = VIL
90
20
30
ns
ns
ns
ns
(3)(4)
tOE
(2)(5)
tDF
OE or CE high to output float, whichever occurred first
tOH
Output hold from address, CE or OE/VPP,whichever occurred first
0
Atmel AT27C080
4
0360N–EPROM–042015