Switching Specifications (AC)
Over recommended operating T = -40°C to 85°C, unless otherwise specified.
A
Parameter
Sym.
Min.
Typ.
Max.
Units
Conditions
Note
Turn On Time
TON
0.07
0.2
ms
IF =5mA, IO=50mA, TA=25C
0.5
0.5
0.8
0.2
ms
ms
ms
ms
IF =5mA, IO=50mA
0.15
0.07
IF =2mA, IO=50mA, TA=25C
IF =2mA, IO=50mA
Turn Off Time
TOFF
IF =5mA, IO=50mA, TA=25C
0.5
0.2
0.5
ms
IF =5mA, IO=50mA
0.07
ms
IF =2mA, IO=50mA, TA=25C
IF =2mA, IO=50mA
ms
Output Transient
Rejection
dVO/dt
1
1
7
kV/s
VO=250V, TA=25C
Input-Output
dVI-O/dt
10
kV/s
VI-O=1000V, TA=25C
Transient Rejection
Notes:
1. For qualified device performance over temperature range, it is recommended to operate at I =5mA.
F
2. Device is considered as a two terminal device: pins 1, 2, 3 and 4 shorted together and pins 5, 6, 7 and 8 shorted together.
3. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your
equipment level safety specification, or Avago Technologies Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
4. The PCB design and environmental conditions are taken into consideration when measuring the I
performance.
O(OFF)
5. During the pulsed R
measurement ( I duration 30ms), ambient (T ) and case temperature (T ) are equal.
O A C
(ON)
For product information and a complete list of distributors, please go to our web site:
www.avagotech.com
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries.
Data subject to change. Copyright © 2005-2012 Avago Technologies. All rights reserved.