5秒后页面跳转
ARE10NIL03Z PDF预览

ARE10NIL03Z

更新时间: 2022-04-20 18:04:56
品牌 Logo 应用领域
松下 - PANASONIC 继电器微波
页数 文件大小 规格书
5页 120K
描述
2.6 GHz SMALL MICROWAVE RELAYS

ARE10NIL03Z 数据手册

 浏览型号ARE10NIL03Z的Datasheet PDF文件第1页浏览型号ARE10NIL03Z的Datasheet PDF文件第2页浏览型号ARE10NIL03Z的Datasheet PDF文件第3页浏览型号ARE10NIL03Z的Datasheet PDF文件第4页 
RE (ARE)  
• 75type  
CAD Data  
Schematic (Top view)  
20.2  
.795  
(0.7)  
(.028)  
NC  
COM  
NO  
14 13 12 11 10  
9 8  
0.5  
.020  
11.2  
.441  
13.2  
.520  
1
7
Direction indication  
(1.3)  
(.511)  
(Deenergized condition)  
0.3  
0.3  
8.6  
9.6  
.378  
.012  
.012  
.339  
0.3  
.012  
(1.49)  
(.059)  
(2.09)  
(.082)  
2.54  
.100  
0.5  
.020  
7.62  
.300  
General tolerance: 0.3 .012  
Note: Please consult us regarding recommended PC board patterns.  
NOTES  
1. Coil operating power  
(2) IR (infrared reflow) soldering method  
(1) Temperature:  
Pure DC current should be applied to the  
coil. The wave form should be  
rectangular. If it includes ripple, the ripple  
factor should be less than 5%.  
However, check it with the actual circuit  
since the characteristics may be slightly  
different.  
–40 to +70°C –40 to +158°F  
(2) Humidity: 5 to 85% RH  
(Avoid freezing and condensation.)  
The humidity range varies with the  
temperature. Use within the range  
indicated in the graph below.  
(3) Atmospheric pressure: 86 to 106 kPa  
Temperature and humidity range for  
usage, transport, and storage:  
T3  
T1=155 to 165°C  
311 to 329°F  
T2  
T2=180 to 200°C  
356 to 392°F  
T3=245°C max.  
473°F max.  
t1=within 120s  
t2=within 30s  
T1  
t1  
t2  
Temperature rise of relay itself may vary  
according to the mounting level or the  
heating method of reflow equipment.  
Therefore, please set the temperature of  
soldering portion of relay terminal and  
the top surface of the relay case not to  
exceed the above mentioned soldering  
condition.  
It is recommended to check the  
temperature rise of each portion under  
actual mounting condition before use.  
4. Packing style  
2. Cleaning  
For automatic cleaning, the boiling  
method is recommended. Avoid  
ultrasonic cleaning which subjects the  
relays to high frequency vibrations, which  
may cause the contacts to stick.  
It is recommended that alcoholic solvents  
be used.  
Humidity, %R.H.  
85  
Tolerance range  
(Avoid freezing (Avoid  
when used at  
temperatures  
lower than  
0°C 32°F)  
condensation  
when used at  
temperatures  
higher than  
0°C 32°F)  
3. Soldering  
(Standard PC board terminal)  
1) The manual soldering shall be  
performed under following condition.  
Max. 260°C 500°F 10s  
5
–40  
–40  
0
70  
+158  
+32  
Temperature, °C °F  
1) Tape dimensions  
1.5+00.1 .059+0.004 dia.  
Max. 350°C 662°F 3s  
2) Condensation  
4
1.75  
.069  
2.0 0.15  
0.4  
.157  
The affect of the PCB on the relay will  
differ depending on the type of PCB  
used. Please verify the type of PCB to be  
used.  
Preheat according to the following  
conditions.  
Relay polarity bar  
.079 .006  
.016  
Condensation forms when there is a  
sudden change in temperature under  
high temperature and high humidity  
conditions. Condensation will cause  
deterioration of the relay insulation.  
3) Freezing  
Condensation or other moisture may  
freeze on the relay when the temperature  
is lower than 0°C 32°F. This causes  
problems such as sticking of movable  
parts or operational time lags.  
4) Low temperature, low humidity  
environments  
44 0.3  
20.2  
.795  
1.732 .012  
20.75  
.817  
1.7  
40.4  
1.591  
.067  
R0.75  
.030  
1.5 .059  
RE Relay  
20.0  
.787  
13.85  
.545  
10.6+00..32  
.417+..000128  
Tape coming out direction  
Temperature  
120°C 248°F or less  
2) Dimensions of plastic reel  
Time  
Within 2 minute  
Soldering should be done at 260 5°C  
500 9°F within 6 s.  
2) In case of automatic soldering, the  
following conditions should be observed  
(Surface-mount terminal)  
21 0.8 dia.  
.827 .031 dia.  
Max. 95  
3.740  
380 0.2  
14.961 .008  
13 0.2 dia.  
.512 .008 dia.  
2.0 0.5  
(1) Position of measuring temperature  
The plastic becomes brittle if the relay is  
exposed to a low temperature, low  
humidity environment for long periods of  
time.  
.079 .020  
45.5+00.2  
1.791+.0008  
Max. 51.7  
2.035  
A
5. Conditions for operation, transport  
and storage conditions  
1) Ambient temperature, humidity, and  
atmospheric pressure during usage,  
transport, and storage of the relay:  
A: Surface of PC board where relay is mounted.  
For general cautions for use, please  
refer to the “General Application  
Guidelines”.  
ASCTB104E 201202-T  
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/  

与ARE10NIL03Z相关器件

型号 品牌 描述 获取价格 数据表
ARE10NIL06NIL PANASONIC 2.6 GHz SMALL MICROWAVE RELAYS

获取价格

ARE10NIL06Z PANASONIC 2.6 GHz SMALL MICROWAVE RELAYS

获取价格

ARE10NIL09NIL PANASONIC 2.6 GHz SMALL MICROWAVE RELAYS

获取价格

ARE10NIL09Z PANASONIC 2.6 GHz SMALL MICROWAVE RELAYS

获取价格

ARE10NIL12NIL PANASONIC 2.6 GHz SMALL MICROWAVE RELAYS

获取价格

ARE10NIL12Z PANASONIC 2.6 GHz SMALL MICROWAVE RELAYS

获取价格