LZ (ALZ)
TYPES
Flux-resistant type
Sealed type
Contact arrangement
Coil voltage
Class B insulation
Class F insulation
Part No.
Class B insulation
Part No.
Class F insulation
Part No.
Part No.
5 V DC
9 V DC
ALZ11B05W
ALZ11B09W
ALZ11B12W
ALZ11B18W
ALZ11B24W
ALZ11B48W
ALZ51B05W
ALZ51B09W
ALZ51B12W
ALZ51B18W
ALZ51B24W
ALZ51B48W
ALZ11F05W
ALZ11F09W
ALZ11F12W
ALZ11F18W
ALZ11F24W
ALZ11F48W
ALZ51F05W
ALZ51F09W
ALZ51F12W
ALZ51F18W
ALZ51F24W
ALZ51F48W
ALZ12B05W
ALZ12B09W
ALZ12B12W
ALZ12B18W
ALZ12B24W
ALZ12B48W
ALZ52B05W
ALZ52B09W
ALZ52B12W
ALZ52B18W
ALZ52B24W
ALZ52B48W
ALZ12F05W
ALZ12F09W
ALZ12F12W
ALZ12F18W
ALZ12F24W
ALZ12F48W
ALZ52F05W
ALZ52F09W
ALZ52F12W
ALZ52F18W
ALZ52F24W
ALZ52F48W
12 V DC
18 V DC
24 V DC
48 V DC
5 V DC
1 Form C
9 V DC
12 V DC
18 V DC
24 V DC
48 V DC
1 Form A
(New PC board terminal)
Standard packing: Carton: 100 pcs.; Case: 500 pcs.
Notes: 1. Tube packing type is also available. Please consult us.
2. Carton packing symbol “W” is not marked on the relay.
3. EN60335-1 GWT compliant types available. When ordering, please add suffix “T”.
Ex. ALZ51F12TW
RATING
1. Coil data
Nominal operating
current
[ 10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F)
5 V DC
9 V DC
80 mA
44.4 mA
33.3 mA
22.2 mA
16.7 mA
8.3 mA
63Ω
203Ω
360Ω
810Ω
1,440Ω
5,760Ω
Max. 70%V
nominal voltage
(Initial)
Min. 10%V
nominal voltage
(Initial)
12 V DC
18 V DC
24 V DC
48 V DC
130%V of
nominal voltage
400 mW
2. Specifications
Characteristics
Item
Specifications
Arrangement
Contact resistance (Initial)
Contact material
1 Form C, 1 Form A
Contact
Max. 100 mΩ (By voltage drop 6V DC 1A)
AgSnO2 type
16A 250V AC
4,000V A
440V AC
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Rating
Max. switching current
16A
Nominal operating power
400mW
Min. switching capacity*1
100mA 5V DC
Insulation resistance (Initial)
Min. 1,000 MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1 min. (Detection current: 10mA)
Between open contacts
Breakdown voltage
(Initial)
Between contacts and coil
5,000 Vrms for 1 min. (Detection current: 10mA)
Max. 55°C 131°F
Electrical
characteristics
Temperature rise (coil)
[with nominal coil voltage and at 16A contact carrying current (resistance method) at 20°C 68°F]
Surge breakdown voltage*2
(Between contacts and coil) (Initial)
10,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
Release time (at nominal voltage) (at 20°C 68°F)
Max. 15ms (excluding contact bounce time)
Max. 5ms (excluding contact bounce time, without diode)
100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
1,000 m/s2 (Half-wave pulse of sine wave: 6ms)
Functional
Shock resistance
Destructive
Mechanical
characteristics
10 to 55Hz at double amplitude of 1.5mm (Detection time: 10µs)
(Only the N.C. side of 1 Form C is 0.8mm)
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Electrical (at 20 times/min.)*3
10 to 55Hz at double amplitude of 1.5mm
Min. 107
N.O.: Min. 105, N.C.: Min. 5 × 104
Expected life
Ambient temperature: –40°C to +85°C –40°F to +185°F (Class B),
Conditions for operation, transport and storage*4, *5
Max. operating speed
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Unit weight
20 times/min. (at nominal switching capacity)
Approx. 12 g .42 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.2 × 50µs according to JEC-212-1981.
*3. In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib. More detail, please look at caution for NOTES.
*4. Class F type is ambient temperature 105°C 221°F.
*5. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*Please note that some of the specifications listed above may not comply with overseas standards.
ASCTB203E 201209-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/