AFL120XXS Series
Dynamic Characteristics -55°C < TCASE < +125°C, VIN=120V unless otherwise specified.
Group A
Parameter
Subgroups
Test Conditions
Min
Nom
Max
Unit
LOAD TRANSIENT RESPONSE
Note 2, 8
4, 5, 6
4, 5, 6
Load Step 50%
Load Step 10%
100%
50%
-450
-450
450
200
mV
µSec
AFL12005S
AFL12008S
AFL12009S
AFL12012S
AFL12015S
AFL12028S
Amplitude
Recovery
4, 5, 6
4, 5, 6
450
400
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 50%
Load Step 10%
100%
50%
-500
-500
500
200
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
500
400
mV
µSec
Amplitude
Recovery
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 50%
Load Step 10%
100%
50%
-600
-600
600
200
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
600
400
mV
µSec
4, 5, 6
4, 5, 6
Load Step 50%
Load Step 10%
100%
50%
-750
-750
750
200
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
750
400
mV
µSec
Amplitude
Recovery
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 50%
Load Step 10%
100%
50%
-750
-750
750
200
mV
µSec
4, 5, 6
4, 5, 6
750
400
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
Load Step 50%
Load Step 10%
100%
50%
-1200
-1200
1200
200
mV
µSec
Amplitude
Recovery
4, 5, 6
4, 5, 6
1200
400
mV
µSec
Amplitude
Recovery
LINE TRANSIENT RESPONSE
Note 1, 2, 3
V
Step = 80
160 Volts
-500
500
500
mV
µSec
Amplitude
Recovery
IN
TURN-ON CHARACTERISTICS
V
= 30, 50, 80 Volts. Note 4
IN
Overshoot
Delay
4, 5, 6
4, 5, 6
Enable 1, 2 on. (Pins 4, 12 high or
open)
250
120
mV
mSec
50
50
75
60
LOAD FAULT RECOVERY
LINE REJECTION
Same as Turn On Characteristics.
MIL-STD-461D, CS101, 30Hz to
dB
50KHz
Note 1
Notes to Specifications:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Parameters not 100% tested but are guaranteed to the limits specified in the table.
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of VOUT at 50% load.
Line transient transition time ≥ 100 µSec.
Turn-on delay is measured with an input voltage rise time of between 100 and 500 volts per millisecond.
Current limit point is that condition of excess load causing output voltage to drop to 90% of nominal.
Parameter verified as part of another test.
All electrical tests are performed with the remote sense leads connected to the output leads at the load.
Load transient transition time ≥ 10 µSec.
Enable inputs internally pulled high. Nominal open circuit voltage ≈ 4.0VDC.
4
www.irf.com