5秒后页面跳转
AFL12005DZ/CH PDF预览

AFL12005DZ/CH

更新时间: 2024-02-27 18:35:47
品牌 Logo 应用领域
其他 - ETC 转换器输出元件
页数 文件大小 规格书
10页 121K
描述
DC to DC Converter

AFL12005DZ/CH 技术参数

是否无铅: 不含铅是否Rohs认证: 符合
生命周期:Obsolete零件包装代码:MODULE
包装说明:,针数:12
Reach Compliance Code:compliantECCN代码:EAR99
风险等级:5.18模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE
最大输入电压:160 V最小输入电压:80 V
标称输入电压:120 VJESD-30 代码:R-XDMA-P12
最大负载调整率:1%功能数量:1
输出次数:1端子数量:12
最高工作温度:85 °C最低工作温度:-20 °C
最大输出电压:6 V标称输出电压:5 V
封装主体材料:UNSPECIFIED封装形状:RECTANGULAR
封装形式:MICROELECTRONIC ASSEMBLY峰值回流温度(摄氏度):260
认证状态:Not Qualified表面贴装:NO
技术:HYBRID温度等级:OTHER
端子形式:PIN/PEG端子位置:DUAL
处于峰值回流温度下的最长时间:40最大总功率输出:80 W
微调/可调输出:YESBase Number Matches:1

AFL12005DZ/CH 数据手册

 浏览型号AFL12005DZ/CH的Datasheet PDF文件第4页浏览型号AFL12005DZ/CH的Datasheet PDF文件第5页浏览型号AFL12005DZ/CH的Datasheet PDF文件第6页浏览型号AFL12005DZ/CH的Datasheet PDF文件第8页浏览型号AFL12005DZ/CH的Datasheet PDF文件第9页浏览型号AFL12005DZ/CH的Datasheet PDF文件第10页 
AFL120XXD Series  
When operating in the shared mode, it is important that A conservative aid to estimating the total heat sink surface  
symmetry of connection be maintained as an assurance of area (AHEAT SINK) required to set the maximum case temp-  
optimum load sharing performance. Thus, converter out- erature rise (T) above ambient temperature is given by  
puts should be connected to the load with equal lengths of the following expression:  
wire of the same gauge and should be connected to a com-  
mon physical point, preferably at the load along with the  
1.43  
T  
converter output and return leads. All converters in a par-  
alleled set must have their share pins connected together.  
This arrangement is diagrammatically illustrated in Figure  
III. showing the output and return pins connected at a star  
point which is located close as possible to the load.  
A
HEAT SINK  
3.0  
0.85  
80P  
where  
T = Case temperature rise above ambient  
As a consequence of the topology utilized in the current  
sharing circuit, the share pin may be used for other func-  
tions. In applications requiring only a single converter, the  
voltage appearing on the share pin may be used as a “totall  
current monitor”. The share pin open circuit voltage is nomi-  
nally +1.00v at no load and increases linearly with increas-  
ing total output current to +2.20v at full load. Note that the  
current we refer to here is the total output current, that is,  
the sum of the positive and negative outout currents.  
1
P = Device dissipation in Watts = POUT  
Eff  
1  
As an example, assume that it is desired to operate an  
AFL12015D while holding the case temperature at TC  
+85°C in an area where the ambient temperature is held to  
a constant +25°C; then  
T = 85 - 25 = 60°C  
Thermal Considerations  
Because of the incorporation of many innovative techno-  
logical concepts, the AFL series of converters is capable of  
providing very high output power from a package of very  
small volume. These magnitudes of power density can only  
be obtained by combining high circuit efficiency with effec-  
tive methods of heat removal from the die junctions. This  
requirement has been effectively addressed inside the de-  
vice; but when operating at maximum loads, a significant  
amount of heat will be generated and this heat must be  
conducted away from the case. To maintain the case tem-  
perature at or below the specified maximum of 125°C, this  
heat must be transferred by conduction to an appropriate  
heat dissipater held in intimate contact with the converter  
base-plate.  
From the Specification Table, the worst case full load effi-  
ciency for this device is 83% @ 100 watts: thus, power  
dissipation at full load is given by  
1
P = 100•  
1 = 1000.205 = 20.5W  
(
)
.83  
and the required heat sink area is  
1.43  
60  
A
HEAT SINK  
=
3.0 = 56.3 in2  
8020.50.85  
Since the effectiveness of this heat transfer is dependent  
on the intimacy of the baseplate/heatsink interface, it is  
strongly recommended that a high thermal conductivity heat  
transferring medium is inserted between the baseplate and  
heatsink. The material most frequently utilized at the fac-  
tory during all testing and burn-in processes is sold under  
Thus, a total heat sink surface area (including fins, if any) of  
2
56 in in this example, would limit case rise to 60°C above  
ambient. A flat aluminum plate, 0.25" thick and of approxi-  
2
mate dimension 4" by 7" (28 in per side) would suffice for  
1
the trade name of Sil-Pad 400 . This particular product is  
this application in a still air environment. Note that to meet  
the criteria in this example, both sides of the plate require  
unrestricted exposure to the +25°C ambient air.  
an insulator but electrically conductive versions are also  
available. Use of these materials assures maximum sur-  
face contact with the heat dissipater thereby compensating  
for any minor surface variations. While other available types  
of heat conductive materials and thermal compounds pro-  
vide similar effectiveness, these alternatives are often less  
convenient and can be somewhat messy to use.  
1
Sil-Pad is a registered Trade Mark of Bergquist, Minneapolis, MN  
www.irf.com  
7

与AFL12005DZ/CH相关器件

型号 品牌 描述 获取价格 数据表
AFL12005DZ/CHPBF INFINEON DC-DC Regulated Power Supply Module, 2 Output, 80W, Hybrid, 0.380 INCH, LOW PROFILE, SEAM

获取价格

AFL12005DZ/ES INFINEON DC-DC Regulated Power Supply Module, 2 Output, 80W, Hybrid, 0.380 INCH, LOW PROFILE, SEAM

获取价格

AFL12005DZ/ESPBF INFINEON DC-DC Regulated Power Supply Module, 2 Output, 80W, Hybrid, 0.380 INCH, LOW PROFILE, SEAM

获取价格

AFL12005DZ/HB ETC DC to DC Converter

获取价格

AFL12005DZ/HBPBF INFINEON DC-DC Regulated Power Supply Module, 2 Output, 80W, Hybrid, 0.380 INCH, LOW PROFILE, SEAM

获取价格

AFL12005DZ-CH INFINEON ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS

获取价格