2. Specifications
Characteristics
Specifications
80A type 120 A type
Item
10A type
20A type
200 A type
300 A type
Contact arrangement
1 Form A
Nominal switching capacity
(resistive load)
120A 400V DC
(Carry current)
10A 400V DC
20A 400V DC
80A 400V DC
200A 400V DC
300A 400V DC
15A 2min,
30A 30sec
(2mm2)
120A 15min,
180A 2min
(15mm2)
225A 3min,
400A 30sec.
(38mm2)
400A 10min,
600A 1min.
(100mm2)
40A 10min,
300A 15min,
(60mm2)
Short term current
60A 1min (3mm2)
Min. switching capacity
(resistive load)*1
1A 12V DC*1
1A 12V DC*1
—
1A 12V DC*1
1A 12V DC*1
1A 12V DC*1
1A 24V DC*1
800A 300V DC
(Min. 1 cycle)*2, 5
1,200A 300V DC 2,000A 350V DC 2,500A 300V DC
Max. cut-off current*5
—
(Min. 1 cycle)*2, 5
(Min. 1 cycle)*2, 5 (Min. 3 cycles)*3, 5
Contact rating
800A 300V DC
(Min. 5 cycles)*2, 5
120A 400V DC
(Min. 50
30A 400V DC
(Min. 50
60A 400V DC
(Min. 50
120A 400V DC
(Min. 50
Overload opening/closing
rating*5
600A 400V DC
(Min. 300 cycles)
—
cycles)*2, 5
cycles)*2, 5
cycles)*2, 5
cycles)*2, 5
–120A 200V DC
(Min. 50
–120A 200V DC
(Min. 50
–200A 200V DC
–300A 200V DC
(Min. 1,000
Reverse direction cut-off*5
Contact voltage drop (Initial)
—
—
(Min. 100 cycles)
cycles)*2, 5
cycles)*2, 5
cycles)*2, 5
Max. 0.5V
(By voltage drop
6 V DC 10A)
Max. 0.2V
(By voltage drop
6 V DC 20A)
Max. 0.067V
(By voltage drop
6 V DC 20A)
Max. 0.03V
(By voltage drop
6 V DC 20A)
Max. 0.1V
(200 A Carry
current)
Max. 0.06V
(300 A Carry
current)
Insulation resistance (Initial)
Between open
Min. 100MΩ (at 500 V DC, Measurement at same location as “Initial breakdown voltage” section.)
2,500Vrms/min. (Detection current: 10mA)
Breakdown
contacts
voltage
Between
(Initial)
2,500Vrms/min. (Detection current: 10mA)
contact and coil
Max. 30ms
(Nominal coil
voltage applied to
the coil, excluding
contact bounce
time.)
Electrical
characteristics
Max. 50ms
Operate time (at 20°C 68°F)
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 10ms
(Nominal coil
voltage applied to
the coil, without
diode.)
Max. 30ms
Release time (at 20°C 68°F)
(Nominal coil voltage applied to the coil, without diode.)
Min. 196m/s2 {20
G} (Half-wave
pulse of sine
wave: 11ms;
detection time:
10µs)
For ON: Min. 196m/s2 {20 G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Functional
Shock
resistance
For OFF: Min. 98m/s2 {10 G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Destructive
Functional
Min. 490 m/s2 {50 G} (Half-wave pulse of sine wave: 6ms)
10 to 200 Hz,
Mechanical
characteristics
Min. 44 m/s2
10 to 200 Hz, Min.43 m/s2 {4.4 G} (Detection time: 10µs)
{4.5 G} (Detection
time: 10µs)
Vibration
resistance
10 to 200 Hz,
Min. 44 m/s2
10 to 200 Hz, Min.43 m/s2 {4.4 G}
(Time of vibration for each direction; X, Y, Z direction: 4 hours)
{4.5 G} (Time of
vibration for each
direction; X, Y, Z
direction: 4 hours)
Destructive
Mechanical
Min. 105
Min. 2×105
Expected life
10A 400V DC
Min. 75,000*2
20A 400V DC
Min. 3,000*2
80A 400V DC
Min. 1,000*2
30A 400V DC
Min. 3,000*2
200A 400V DC
Min. 3,000*2
300A 400V DC
Min. 1,000
Electrical (resistive load)
Ambient temperature:
Ambient temperature:
–40 to +80°C –40 to +176°F (Storage: Max. 85°C 185°F),
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
–40 to +85°C –40 to +185°F
Conditions for operation,
transport and storage
Conditions
(Storage: Max.85°C 185°F),
Humidity: 5 to 85% R.H. (Not freezing
and condensing at low temperature)
Mass (Approx.)
90 g 3.17 oz
180 g 6.35 oz
400 g 14.11 oz
400 g 14.11 oz
600 g 21.16 oz
750 g 26.46 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The electrical load performance value for the 10A, 20A, 80A, 120A and 200A types applies when a varistor is connected in parallel to the coil. Please be warned
that working life will be reduced when a diode is used.
*3. Condition: Nominal switching 10 cycles, each cut-off 2,500 A
*4. The coil voltage 12 V DC type and 24 V DC type have the same specifications.
*5. at L/R 1ms
ASCTB233E 201209-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/