ADT7461A
ELECTRICAL CHARACTERISTICS T = −40°C to +125°C, V = 3.0 V to 3.6 V, unless otherwise noted.
A
DD
Parameter
Conditions
Min
Typ
Max
Unit
Power Supply
Supply Voltage, V
3.0
3.30
3.6
V
DD
Average Operating Supply Current, I
0.0625 Conversions/Sec Rate (Note 1)
Standby mode
−
240
5.0
350
30
mA
DD
Undervoltage Lockout Threshold
Power−On−Reset Threshold
Temperature−To−Digital Converter
Local Sensor Accuracy
V
input, disables ADC, rising edge
−
2.55
−
V
V
DD
1.0
−
2.5
0°C ≤ T ≤ +70°C
−
−
1.0
1.5
2.5
°C
A
A
0°C ≤ T ≤ +85°C
−40°C ≤ T ≤ +100°C
A
Resolution
−
−
1.0
−
°C
°C
Remote Diode Sensor Accuracy
0°C ≤ T ≤ +70°C, −55°C ≤ T (Note 2) ≤ +150°C
−
1.0
1.5
2.5
A
D
0°C ≤ T ≤ +85°C, −55°C ≤ T (Note 2) ≤ +150°C
A
D
−40°C ≤ T ≤ +100°C, −55°C ≤ T (Note 2) ≤ +150°C
A
D
Resolution
−
−
0.25
−
−
°C
mA
Remote Sensor Source Current
High level (Note 3)
Middle level (Note 3)
Low level (Note 3)
220
82
13.5
Conversion Time
From stop bit to conversion complete, one−shot
−
−
−
40
6.0
1.5
52
8.0
−
ms
ms
kW
mode with averaging switched on
One−shot mode with averaging off (that is, conversion
rate = 16−, 32−, or 64−conversions per second)
Maximum Series Resistance Cancelled
Resistance split evenly on both the D+ and D– inputs
Open−Drain Digital Outputs (THERM, ALERT/THERM2)
Output Low Voltage, V = −6.0 mA
I
−
−
−
0.4
1.0
V
OL
OUT
High Level Output Leakage Current, I
V
OUT
= V
DD
0.1
mA
OH
SMBus Interface (Note 3 and 4)
Logic Input High Voltage, V SCLK, SDATA
3.0 V ≤ V ≤ 3.6 V
2.1
−
−
−
−
0.8
−
V
V
IH
DD
Logic Input Low Voltage, V SCLK, SDATA
3.0 V ≤ V ≤ 3.6 V
IL
DD
Hysteresis
−
500
−
mV
mA
mA
pF
kHz
ms
ms
SDA Output Low Voltage, V
−
0.4
+1.0
−
OL
Logic Input Current, I , I
−1.0
−
−
IH IL
SMBus Input Capacitance, SCLK, SDATA
SMBus Clock Frequency
5.0
−
−
400
64
SMBus Timeout (Note 5)
User programmable
−
25
−
SCLK Falling Edge to SDATA Valid Time
Master clocking in data
−
1.0
1. See Table 5 for information on other conversion rates.
2. Guaranteed by characterization, but not production tested.
3. Guaranteed by design, but not production tested.
4. See SMBus Timing Specifications section for more information.
5. Disabled by default. Detailed procedures to enable it are in the Serial Bus Interface section of the datasheet.
http://onsemi.com