PF (ADP1)
SPECIFICATIONS
Type
Economy type
(Without glass base)
Standard type (With glass base)
Gauge pressure
Type of pressure
Pressure medium
Air (For other medium, please consult us.)
4.9
14.7
0.15
34.3
0.35
49.0
0.5
98.1
1.0
196.1
2.0
343.2
3.5
490.3
5.0
833.6
8.5
980.7
10.0
40.0
0.4
49.0
0.5
Unit: kPa
Unit: kgf/cm2 (approx.)
Rated
pressure
0.05
Twice the rated pressure
5000±1000 Ω
1.5 times the rated pressure Twice the rated pressure
3300±600 Ω 5000±1000 Ω
Max. applied pressure
Bridge resistance
–5 to 50°C –20 to 100°C
–7 to 122°F –4 to 212°F
–20 to 100°C –4 to 212°F (no freezing or condensation)
–40 to 120°C –40 to 248°F (no freezing or condensation)
0 to 50°C 32 to 122°F
Ambient temperature
–20 to 70°C –40 to 120°C
–4 to 158°F –70 to 248°F
Storage temperature
5 to 45°C 0 to 50°C
41 to 113°F 32 to 122°F
Temperature compensation range
1.5 mA DC
100±40 mV
Drive current (constant current)
Output span voltage
Offset voltage
40±20 mV
43.5±22.5 mV 85±45 mV
±20 mV
±15 mV
±25 mV
±0.7%FS ±0.5%FS
±0.6%FS ±0.4%FS
±0.3%FS
±0.2%FS
±0.5%FS
±0.6%FS
±0.4%FS
±0.3%FS
Linearity
±0.7%FS
Pressure hysteresis
Offset voltage-temperature
characteristics (0 to 50°C 32 to 122°F)
±15%FS
±10%FS
±5.0%FS
±2.5%FS
±10%FS ±8%FS
Sensitivity-temperature
characteristics (0 to 50°C 32 to 122°F)
±1.3%FS ±2.5%FS
Notes) 1. Unless otherwise specified, measurements were taken with a drive current of1.5 mA ±0.01 mA at a temperature of 25°C 77°F and humidity ranging from 25% to
85%.
2. Please consult us if a pressure medium other than air is to be used.
3. This is the regulation which applies within the compensation temperature range.
4. Please consult us if the intended use involves a negative pressure.
DATA
1. Characteristics data
1-<1> Output characteristics
1-<2> Offset voltage – temperature
1-<3> Sensitivity – temperature
characteristics
ADP1141
characteristics (%FS)
ADP1141
ADP1141
Drive current: 1.5 mA; temperature: 25°C 77°F
Drive current: 1.5 mA; rating ±5%FS
Drive current: 1.5 mA; rating ±2.5%FS
100
4
4
80
60
3
3
2
1
2
1
40
20
0
0
0
–1
–1
–20
–40
–2
–2
0
49 {0.5}
98.1 {1}
Rated pressure
0
25
47
50
0
32
25
47
50
122
32
122
kpa {kgf/cm2}
Temperature (°C °F)
Temperature (°C °F)
2. Pressure cycle range (0 to rated pressure)
Tested sample: ADP1131, temperature: 25°C 77°F
2-<1> Offset voltage range
2-<2> Output span voltage range
2
2
Even after testing for 1 million times, the vari-
ations in the offset voltage and output span
voltage are minimal.
1
0
1
0
–1
–1
–2
–2
5
5
6
5
5
6
0
1×10
5×10 1×10
0
1×10
5×10 1×10
Pressure cycle (cycle)
Pressure cycle (cycle)
28