ADL5363
5 V PERFORMANCE
VS = 5 V, IS = 100 mA, TA = 25°C, fRF = 2535 MHz, fLO = 2738 MHz, LO power = 0 dBm, VGS0 = VGS1 = 0 V, and ZO = 50 Ω, unless
otherwise noted.
Table 3.
Parameter
Test Conditions/Comments
Min
Typ
Max
Unit
DYNAMIC PERFORMANCE
Power Conversion Loss
SSB Noise Figure
Including 1:1 IF port transformer and PCB loss
7.7
7.6
31
dB
dB
dBm
Input Third-Order Intercept (IIP3)
fRF1 = 2534.5 MHz, fRF2 = 2535.5 MHz, fLO = 2738 MHz,
each RF tone at 0 dBm
Input Second-Order Intercept (IIP2)
fRF1 = 2535 MHz, fRF2 = 2585 MHz, fLO = 2738 MHz,
each RF tone at 0 dBm
62
dBm
Input 1 dB Compression Point (IP1dB)1 Exceeding 20 dBm RF power results in damage to the device
25
dBm
dBm
dBm
dBc
dBc
dBc
LO-to-IF Leakage
LO-to-RF Leakage
RF-to-IF Isolation
IF/2 Spurious
Unfiltered IF output
−22
−32
−44
−61
−70
−10 dBm input power
−10 dBm input power
IF/3 Spurious
POWER SUPPLY
Positive Supply Voltage
Quiescent Current
4.5
5
100
5.5
V
mA
VS = 5 V
1 Exceeding 20 dBm RF power results in damage to the device.
3.3 V PERFORMANCE
VS = 3.3 V, IS = 60 mA, TA = 25°C, fRF = 2535 MHz, fLO = 2738 MHz, LO power = 0 dBm, R9 = 226 Ω, VGS0 = VGS1 = 0 V, and ZO = 50 Ω,
unless otherwise noted.
Table 4.
Parameter
Test Conditions/Comments
Min
Typ
Max
Unit
DYNAMIC PERFORMANCE
Power Conversion Loss
SSB Noise Figure
Including 1:1 IF port transformer and PCB loss
7.4
6.8
26
dB
dB
dBm
Input Third-Order Intercept (IIP3)
fRF1 = 2534.5 MHz, fRF2 = 2535.5 MHz, fLO = 2738 MHz,
each RF tone at 0 dBm
Input Second-Order Intercept (IIP2)
fRF1 = 2535 MHz, fRF2 = 2585 MHz, fLO = 2738 MHz,
each RF tone at 0 dBm
56
dBm
POWER SUPPLY
Positive Supply Voltage
Quiescent Current
3.3
60
V
mA
VS = 5 V
Rev. 0 | Page 4 of 24