描述
14-Channel, High-Voltage Data-Acquisition Systems

ADES1754 数据手册

 浏览型号ADES1754的Datasheet PDF文件第2页浏览型号ADES1754的Datasheet PDF文件第3页浏览型号ADES1754的Datasheet PDF文件第4页浏览型号ADES1754的Datasheet PDF文件第5页浏览型号ADES1754的Datasheet PDF文件第6页浏览型号ADES1754的Datasheet PDF文件第7页 
ADES1754/ADES1755/ADES1756  
General Description  
The ADES1754/ADES1755/ADES1756 are flexible  
data-acquisition systems for the management of high-  
voltage and low-voltage battery modules. The systems  
can measure 14 cell voltages and a combination of six  
temperatures or system voltage measurements with fully  
redundant measurement engines in 162µs, or perform  
all inputs solely with the ADC measurement engine in  
99μs. Fourteen internal balancing switches rated  
for >300mA for cell-balancing current support extensive  
built-in diagnostics. Up to 32 devices can be daisy-  
chained to manage 448 cells and monitor 192  
temperatures.  
14-Channel, High-Voltage Data-  
Acquisition Systems  
Benefits and Features  
65V Operating Voltage  
Ultra-Low Power Operation  
• Shutdown Mode: 2μA  
Redundant ADC and Comparator (COMP)  
Acquisitions  
Simultaneous Cell and Bus-Bar Voltage Acquisitions  
14 Cell-Voltage Measurement Channels  
2.2mV/5mV/10mV Accuracy (-40°C to +105°C)  
1.8mV Accuracy (+5°C to +65°C)  
14 Cell-Balancing Switches  
>300mA Software-Programmable Balancing  
Current  
Cell and bus-bar voltages ranging from -2.5V to +5V are  
measured differentially over a 65V common-mode  
range, with a typical accuracy of 100µV. If oversampling  
is enabled, up to 128 measurements per channel can be  
averaged internally with 14-bit resolution and combined  
with digital post-processing IIR filtering for increased  
noise immunity.  
Automated Balancing with Individual Cell Timers  
Automated Balancing by Cell Voltage  
Emergency Discharge Mode  
Six Configurable Auxiliary Inputs for Temperature,  
Voltage, or GPIO  
Integrated Die Temperature Measurement  
Automatic Thermal Protection  
Hot Plug-Tolerant without External Protection  
Individually Configurable Safety Alerts  
Overvoltage, Undertemperature Faults  
Undervoltage, Overtemperature Faults  
1-Cell Mismatch Alert  
The system can shut itself down in the event of a thermal  
overload by measuring its own die temperature. The  
system uses Analog Devices' battery-management  
UART protocol for robust communications and supports  
2
an I C controller interface for external device control. It  
is optimized to support a reduced feature set of internal  
diagnostics and rapid-alert communication through both  
embedded communication and hardware-alert interfaces.  
UART, Dual UART Interface  
Battery-Management UART Protocol  
Daisy-Chain up to 32 Devices  
Inductive for Higher Galvanic Isolation  
Up to 2Mbps Baud Rate (Auto-Detect)  
• 1.5μs Propagation Delay per Device  
Packet-Error Checking (PEC)  
Key Applications  
Residential Battery Storage Systems  
High-Voltage Battery Stacks  
Battery-Backup Systems (UPS)  
Super-Cap Systems  
Battery-Powered Tools  
EV Charging  
2
I C Controller  
Configurable Hardware-Alert Interfaces  
32-Bit Unique Device ID  
Ordering Information appears at end of data sheet.  
19-101802; Rev 0; 11/23  
© 2023 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.  

与ADES1754相关器件

型号 品牌 描述 获取价格 数据表
ADES1755 ADI 14-Channel, High-Voltage Data-Acquisition Systems

获取价格

ADES1756 ADI 14-Channel, High-Voltage Data-Acquisition Systems

获取价格

AD-ESD24VC2 CJ SOT-23

获取价格

AD-ESD24VCP CJ SOT-23

获取价格

AD-ESD36VAP CJ SOT-23

获取价格

AD-ESD36VD5 CJ SOD-523

获取价格