ADC200 SERIES
1W, High Isolation SIP, Single & Dual Output DC/DC Converters
Absolute Maximum Ratings
General Characteristics
Parameter
Parameter
Conditions
Min. Max. Units
Min.
3000
Typ.
---
Max.
---
Units
VDC
Isolation
Voltage
60 Seconds
5VDC Input Models
-0.7
9
VDC
Isolation
Resistance
Input Surge Voltage
12VDC Input Models
500VDC
-0.7
18
VDC
10
---
70
---
60
---
GΩ
pF
(1000mS)
Isolation
Capacitance
100kHz, 1V
24VDC Input Models
-0.7
30
VDC
100
120
Lead Temperature
(1.5mm from case for 10sec.)
Switching
Frequency
---
---
260
450
°C
100
kHz
Internal Power Dissipation
mW
MIL-HDBK-217F
@25°C
Ground Benign
MTBF
2
---
---
MHrs
Exceeding the unit absolute maximum ratings could cause damage.
These are not continuous operating ratings.
Environmental Characteristics
Output Characteristics
Conditions
Parameter
Min.
---
Typ.
±1.2
Max.
±1.5
Units
%
Parameter
Conditions
Min. Max. Units
For Vin Change of
1%
Operating
Temperature
Ambient
-40
85
°C
Line Regulation
Operating
Temperature
Io = 20% to 100%
20MHz BW
See Selection Guide
Case
-40
90
°C
Load Regulation
%
Storage
Temperature
mV P-P
-40
---
125
95
°C
%
Ripple & Noise
Short Circuit
---
65
100
0.5 Second Max.
Humidity
Cooling
Free-Air Convection
Maximum Capacitive Load
Units
uF
Derating Curve (3.3, 5 & ±5V Outputs)
Singles
Duals
100
Models by Output Voltage
(Each Output on Duals)
220
100
100LFM
200LFM
400LFM
80
Natural
convection
Notes:
60
40
1. Specifications typical at Ta=+25°C, resistive load, nominal input
voltage, rated output current unless otherwise noted.
2. These power converters require a minimum output load to maintain
specified regulation.
20
0
¡ã
3. Operation under no-load conditions will not damage these modules;
however, they may not meet all specifications listed.
4. All DC/DC converters should be externally fused at the front end for
protection.
5. Other input and output voltage may be available, please contact
factory.
-40
50
60
70
80
90
100
110
Ambient Temperature
]
Derating Curve (Other Outputs)
100
100LFM
400LFM
200LFM
6. All specifications subject to change without notice.
7. For detailed data sheet, please visit our website.
80
60
Natural
convection
40
20
0
¡ã
-40
50
60
70
80
90
100
110
Ambient Temperature
]
2463 208th Street, Ste. 205
Torrance, CA 90501
Tel: (310) 533-1455
Fax: (310) 533-1853
http://www.mpsind.com
E-mail: sales@mpsind.com