AD8223
AD8223A
Typ
AD8223B
Typ
Parameter
GAIN
Conditions
Min
Max
Min
Max
Unit
G = 5 + (80 kΩ/RG)
Gain Range
Gain Error2
G = 5
G = 10
G = 100
G = 1000
Nonlinearity
G = 5
5
1000
5
1000
V/V
VOUT = −10 V to +10 V
0.07
0.3
0.3
0.02
0.2
0.3
%
%
%
%
0.10
0.10
0.10
0.10
0.10
0.10
0.3
0.3
VOUT = −10 V to +10 V
TA = −40°C to +85°C
5
30
5
30
ppm
ppm
G = 1000
Gain vs. Temperature
G = 5
10
2
ppm/°C
ppm/°C
G > 51
50
50
INPUT
Input Impedance
Differential
Common-Mode
Common-Mode Input Voltage
Range3
2||2
2||2
2||2
2||2
GΩ||pF
GΩ||pF
V
VIN+ = VIN−
(−VS) −
0.15
(+VS) −
1.5
(−VS) −
0.15
(+VS) −
1.5
OUTPUT
Output Swing
RL = 10 kΩ to ground (−VS) +
0.3
RL = 100 kΩ to ground (−VS) +
0.1
(+VS) −
0.8
(+VS) −
0.3
(−VS) +
0.3
(−VS) +
0.1
(+VS) −
0.8
(+VS) −
0.3
V
V
REFERENCE INPUT
RIN
IIN
60
+10
20%
+20
+VS
60
+10
20%
+20
+VS
kΩ
μA
V
VIN+ = VIN− = VREF = 0 V
−VS
Voltage Range
Gain to Output
−VS
2
1
1
V
0.0002
0.0002
POWER SUPPLY
Operating Range
Quiescent Current
Over Temperature
TEMPERATURE RANGE
For Specified Performance
2
TA = −40°C to +85°C
−40
12
650
850
12
650
850
V
μA
μA
+85
−40
+85
°C
1 Because maximum supply voltage is 24 V between the negative and positive supply, these specifications at 12V are at the part’s limit. Operation at a nominal supply
voltage slightly less than 12 V is recommended to allow for power supply tolerances.
2 Does not include effects of external resistor, RG.
3 Total input range depends on common-mode voltage, differential voltage, and gain. See Figure 18 through Figure 21 and the Input Voltage Range section in the
Theory of Operation section for more information.
Rev. 0 | Page 6 of 20