描述
【0.5C Accurate, 10-Bit Digital Temperature Sensors in SOT-23

AD7414ARM-1REEL7 技术参数

是否无铅: 含铅是否Rohs认证: 不符合
生命周期:Contact ManufacturerReach Compliance Code:unknown
风险等级:5.74最大精度(摄氏度):3 Cel
主体宽度:3 mm主体高度:0.95 mm
主体长度或直径:3 mm外壳:PLASTIC
JESD-609代码:e0安装特点:SURFACE MOUNT
位数:10最大工作电流:1.2 mA
最高工作温度:125 °C最低工作温度:-40 °C
输出接口类型:2-WIRE INTERFACE封装形状/形式:SQUARE
传感器/换能器类型:TEMPERATURE SENSOR,SWITCH/DIGITAL OUTPUT,SERIAL最大供电电压:5.5 V
最小供电电压:2.7 V表面贴装:YES
端子面层:Tin/Lead (Sn/Pb)端接类型:SOLDER
Base Number Matches:1

AD7414ARM-1REEL7 数据手册

 浏览型号AD7414ARM-1REEL7的Datasheet PDF文件第4页浏览型号AD7414ARM-1REEL7的Datasheet PDF文件第5页浏览型号AD7414ARM-1REEL7的Datasheet PDF文件第6页浏览型号AD7414ARM-1REEL7的Datasheet PDF文件第8页浏览型号AD7414ARM-1REEL7的Datasheet PDF文件第9页浏览型号AD7414ARM-1REEL7的Datasheet PDF文件第10页 
C
 ꢂ74ꢀ4/ ꢂ74ꢀ.  
THEORYCOFCOPER TIONC  
CIRCUIT INFORMATION  
Configuration functions consist of  
The AD7414/AD7415 are standalone digital temperature  
sensors. The on-chip temperature sensor allows an accurate  
measurement of the ambient device temperature to be made.  
The 10-bit analog-to-digital converter converts the temperature  
measured into a twos complement format for storage in the  
temperature register. The ADC is made up of a conventional  
successive-approximation converter based around a capacitor  
digital-to-analog (DAC). The serial interface is I2C-and SMBus-  
compatible. The AD7414/AD7415 require a 2.7 V to 5.5 V  
power supply. The temperature sensor has a working  
measurement range of −40°C to +125°C.  
Switching between normal operation and full power-  
down  
Enabling or disabling the SCL and SDA filters  
Enabling or disabling the ALERT function  
Setting the ALERT pin polarity  
V
V
V
DD  
DD  
DD  
SUPPLY  
2.7V TO  
5.5V  
FUNCTIONAL DESCRIPTION  
10k10k10kΩ  
10µF  
0.1µF  
1kΩ  
Temperature measurement is initiated by two methods. The  
first uses an internal clock countdown of 800 ms, and a  
conversion is performed. The internal oscillator is the only  
circuit that is powered up between conversions, and once it  
times out, every 800 ms, a wake-up signal is sent to power up  
the rest of the circuitry. A monostable is activated at the  
beginning of the wake-up signal to ensure that sufficient time is  
given to the power-up process. The monostable typically takes  
4 µs to time out. It then takes typically 25 µs for each conversion  
to be completed. The new temperature value is loaded into the  
temperature value register and ready for reading by the I2C  
interface.  
V
DD  
SDA  
SCL  
AS  
µ
C/µP  
GND  
ALERT  
AD7414  
Figure 6. Typical Connection Diagram  
MEASUREMENT TECHNIQUE  
A common method of measuring temperature is to exploit the  
negative temperature coefficient of a diode, or the base-emitter  
voltage of a transistor, operated at constant current.  
Unfortunately, this technique requires calibration to null the  
effect of the absolute value of VBE, which varies from device to  
device. The technique used in the AD7414/AD7415 is to  
measure the change in VBE when the device is operated at two  
different currents. This is given by  
A temperature measurement is also initiated every time the  
one-shot method is used. This method requires the user to  
write to the one-shot bit in the configuration register when a  
temperature measurement is needed. Setting the one-shot bit to  
1 starts a temperature conversion directly after the write  
operation. The track-and-hold goes into hold approximately  
4 µs (monostable time out) after the STOP condition, and a  
conversion is then initiated. Typically 25 µs later, the conversion  
is complete and the temperature value register is loaded with a  
new temperature value.  
VBE = KT q × ln (N)  
where:  
K is Boltzmann’s constant.  
The measurement modes are compared with a high tempera-  
ture limit, stored in an 8-bit read/write register. This is applica-  
ble only to the AD7414, because the AD7415 does not have an  
ALERT pin and subsequently does not have an overtemperature  
monitoring function. If the measurement is greater than the  
high limit, the ALERT pin is activated (if it has already been  
enabled in the configuration register). There are two ways to  
deactivate the ALERT pin again: when the alert reset bit in the  
configuration register is set to 1 by a write operation, and when  
the temperature measured is less than the value in the TLOW  
register. This ALERT pin is compatible with the SMBus  
SMBALERT option.  
q is the charge on the electron (1.6 × 10–19 Coulombs).  
T is the absolute temperature in Kelvins.  
N is the ratio of the two currents.  
Rev. E | Page 7 of 20  
 

与AD7414ARM-1REEL7相关器件

型号 品牌 描述 获取价格 数据表
AD7414ARMZ-0 ADI 【0.5C Accurate, 10-Bit Digital Temperature Se

获取价格

AD7414ARMZ-0REEL ADI 【0.5C Accurate, 10-Bit Digital Temperature Se

获取价格

AD7414ARMZ-0REEL7 ADI 【0.5C Accurate, 10-Bit Digital Temperature Se

获取价格

AD7414ARMZ-1 ADI 【0.5C Accurate, 10-Bit Digital Temperature Se

获取价格

AD7414ARMZ-1 ROCHESTER Serial Switch/Digital Sensor, 10 Bit(s), 3Cel, Square, Surface Mount, MO-187AA, MSOP-8

获取价格

AD7414ARMZ-1REEL ADI 【0.5C Accurate, 10-Bit Digital Temperature Se

获取价格