描述
ANALOG TEMP SENSOR-CURRENT, 0.15Cel, RECTANGULAR, THROUGH HOLE MOUNT, TO-92, 3 PIN

AD592AN 技术参数

Source Url Status Check Date:2013-05-01 14:56:15.021是否无铅: 含铅
是否Rohs认证: 不符合生命周期:Obsolete
包装说明:TO-92, 3 PIN针数:3
Reach Compliance Code:not_compliantECCN代码:EAR99
HTS代码:8542.39.00.01风险等级:5.18
最大精度(摄氏度):0.15 Cel主体宽度:4.06 mm
主体高度:4.85 mm主体长度或直径:5.08 mm
外壳:PLASTICJESD-609代码:e0
线性度(Cel):0.35 Cel安装特点:THROUGH HOLE MOUNT
端子数量:3最高工作温度:105 °C
最低工作温度:-25 °C输出电流标称:298.2 µA
封装主体材料:PLASTIC/EPOXY封装等效代码:SIP3,.1,50
封装形状/形式:ROUND电源:5 V
传感器/换能器类型:TEMPERATURE SENSOR,ANALOG,RESISTANCE BASED子类别:Other Sensors
最大供电电压:30 V最小供电电压:4 V
表面贴装:NO技术:BIPOLAR
端子面层:Tin/Lead (Sn85Pb15)端接类型:SOLDER
Base Number Matches:1

AD592AN 数据手册

 浏览型号AD592AN的Datasheet PDF文件第3页浏览型号AD592AN的Datasheet PDF文件第4页浏览型号AD592AN的Datasheet PDF文件第5页浏览型号AD592AN的Datasheet PDF文件第6页浏览型号AD592AN的Datasheet PDF文件第7页浏览型号AD592AN的Datasheet PDF文件第8页 
AD592  
To minimize the number of MUXs required when a large num-  
ber of AD592s are being used, the circuit can be configured in a  
matrix. That is, a decoder can be used to switch the supply volt-  
age to a column of AD592s while a MUX is used to control  
which row of sensors are being measured. The maximum num-  
ber of AD592s which can be used is the product of the number  
of channels of the decoder and MUX.  
To convert the AD592 output to °C or °F a single inexpensive  
reference and op amp can be used as shown in Figure 17. Al-  
though this circuit is similar to the two temperature trim circuit  
shown in Figure 6, two important differences exist. First, the  
gain resistor is fixed alleviating the need for an elevated tem-  
perature trim. Acceptable accuracy can be achieved by choosing  
an inexpensive resistor with the correct tolerance. Second, the  
AD592 calibration error can be trimmed out at a known conve-  
nient temperature (i.e., room temperature) with a single pot ad-  
justment. This step is independent of the gain selection.  
An example circuit controlling 80 AD592s is shown in Figure  
16. A 7-bit digital word is all that is required to select one of  
the sensors. The enable input of the multiplexer turns all the  
sensors off for minimum dissipation while idling.  
R
R
OFFSET  
GAIN  
R
o
GAIN  
R
9.1kΩ  
9.8kΩ  
C
F
100kΩ  
180kΩ  
COLUMN  
SELECT  
OFFSET  
o
+5V  
R
CAL  
R
AD741  
2.5V  
R
ROW  
SELECT  
+15V  
AD1403  
4028 BCD TO DECIMAL DECODER  
o o  
= 100mV/( C OR F)  
V
OUT  
/R  
OFFSET GAIN  
AD592  
V
OUT  
V–  
10kΩ  
Figure 17. Celsius or Fahrenheit Thermometer  
+15V  
–15V  
E
N
80 – AD592s  
Figure 16. Matrix Multiplexer  
OUTLINE DIMENSIONS  
Dimensions shown in inches and (mm).  
0.205 (5.20)  
0.135  
0.175 (4.96)  
(3.43)  
MIN  
0.210 (5.33)  
0.170 (4.32)  
0.050  
(1.27)  
MAX  
SEATING  
PLANE  
0.019 (0.482)  
0.016 (0.407)  
SQUARE  
0.500  
(12.70)  
MIN  
0.055 (1.39)  
0.045 (1.15)  
0.105 (2.66)  
0.095 (2.42)  
0.105 (2.66)  
0.080 (2.42)  
0.165 (4.19)  
0.125 (3.94)  
1
2
3
0.105 (2.66)  
0.080 (2.42)  
BOTTOM VIEW  
–8–  
REV. A  

与AD592AN相关器件

型号 品牌 描述 获取价格 数据表
AD592ANZ ADI Low Cost, Precision IC Temperature Transducer

获取价格

AD592BN ADI Low Cost, Precision IC Temperature Transducer

获取价格

AD592BN ROCHESTER ANALOG TEMP SENSOR-CURRENT, 0.15Cel, RECTANGULAR, THROUGH HOLE MOUNT, TO-92, 3 PIN

获取价格

AD592BNZ ADI LOW COST, PRECISION IC TEMPERATURE TRANSDUCER

获取价格

AD592CN ADI Low Cost, Precision IC Temperature Transducer

获取价格

AD592CN ROCHESTER ANALOG TEMP SENSOR-CURRENT, 0.15Cel, RECTANGULAR, THROUGH HOLE MOUNT, TO-92, 3 PIN

获取价格