Model Selection Guide
Input
Voltage (VAC)
Universal Range 11ꢀ VAC 230 VAC
Output
Rated
Power
(W)
Overvoltage
Protection
(VDC)
Ripple &
Noise
(mV p-p)
Model
Number
Efficiency
(%, Typ)
Current (A)
Voltage Current (A) Current (A)
(VDC)
Max)
Range
+12 (V1)
+ꢀ (V2)
+24 (V1)
+ꢀ (V2)
48 (V1)
+ꢀ (V2)
28.0
3.0
14.0
3.0
7.0
3.0
0 ~ 28.0
0 ~ 3.0
0 ~ 14.0
0 ~ 3.0
0 ~ 7.0
0 ~ 3.0
14 ~ 16
N/A
27 ~ 30
N/A
ꢀ2 ~ ꢀ6
N/A
100
ꢀ0
1ꢀ0
ꢀ0
2ꢀ0
ꢀ0
AD23601C
AD23602C
360
360
360
100 - 240
100 - 240
100 - 240
1.0
1.0
1.0
0.ꢀ
0.ꢀ
0.ꢀ
78
80
80
AD23603C
Notes:
Derating Curve
1. Load regulation is specified for a load change
of 20% to 100%. For models AD23601C, load
regulation for V1 (12V) is 2%
2. Ripple & noise is measured using equipment with
20 Mhz of bandwidth with the unit under test
operating at rated load and a 110 VAC input.
Connection to the unit is made with a 0.1 μF /
630V metalized capacitor & a 47 μF electrolytic
capacitor connected in parallel.
3. Transient recovery is measured to within a 1%
error band for a load step change of ꢀ0% to
100%.
4. Isolation resistance is given for Input/Output and
Input/FG. For Output/FG., it is ꢀ0 MΩ
ꢀ. Overload protection is power limiting. The
unit recovers automatically when the fault is
removed.
6. Over voltage protection is a shut down type.
The unit recovers automatically when the fault
is removed.
7. To mount the unit to the DIN rail, tilt the unit
rearwards from the top, fitting the mount over
the top of the rail. Press back on the bottom front
of the unit until it locks in place on the rail. To
remove the unit from the rail, pull the removal
clip at the bottom rear of the unit downward
with a screw driver. With the clip down, lift up
on the unit from the bottom front until it clears
the rail. Before installation or removal all wiring
should be disconnected and the main power to
the system shut off.
Mechanical Dimensions
8. When wiring the supply, all lines should be as
thick and short as possible. AWG 14 wire is recom-
mended for the AD2360C series.
9. The units should be mounted so they are vertically
orientated. Air flow (if provided) would optimally
flow from the bottom to the top of the unit.
10. It is recommended that a fuse be used on the
input of a power supply for protection. For
the AD2360C series a 2ꢀ0VAC ꢀ.0A is recom-
mended.
Units with the optional “FT” outputs may be
easily connected for “Fault Tolerant operation.
Contact the factory for details
Connections TB 1
Pin
1
Function
FT (Optional)
2
FT (Optional)
3
+V2 (ꢀV) Output
Output Common
Output Common
+V1 Output
4
ꢀ
6
7
+V1 Output
Connections TB 2
Pin
1
Function
AC Input - Live
2
AC Input - Neutral
Frame Ground (FG
3
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.2ꢀ)
MicroPower Direct
FAX: (781) 344-8481
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
•
E-Mail: sales@micropowerdirect.com