Power Management AAC242/243
PARAMETER
PARAMETERS
TYP.
UNITS
CONDITIONS
MIN.
MAX.
OUTPUT SECTION
Voltage Out Low
0.4
2.2
V
V
Isink = 20mA
Isink = 200mA
Isink = 20mA
Voltage Out Low
Voltage Out High
13.5
12.5
14
V
Voltage Out High
13.5
V
Isink = 200mA
Vcc=6V, Isink = 1mA
CL=1000pF
Voltage Out UVLO
1.1
50
50
V
Voltage Output Rise Time
Voltage Output Fall Time
Current Output Source Peak
Current Output Sink Peak
30
30
ns
ns
A
CL=1000pF
1.2
0.7
A
UNDER-VOLTAGE LOCKOUT SECTION
Voltage Start Threshold (142)
Voltage Start Threshold (143)
Voltage Turnoff Threshold (142)
Voltage Turnoff Threshold (143)
Zener Clamp Voltage
15
7.8
9
16
8.4
10
17
9
V
V
V
V
V
11
8.2
7
7.6
34
30
Icc≤25mA
TOTAL DEVICE SECTION
Start-up Supply Current
0.4
0.6
11
mA
mA
Operating Supply Current
The improved switching performance increases the high peak current associated with internal and external
capacitances and will require careful grounding and PCB trace routing. Bypass and timing capacitors should be of
high quality and located carefully with short traces. The reference capacitor must be located very close to the IC
with minimum trace lengths. A single point ground should be located at pin 5 ground. The use of a good ground
plane is recommended. Under certain conditions of high peak currents it may be advisable to isolate the Vref pin
from the bypass capacitor with a resistor to prevent interaction of the high current with the internal oscillator
operation.
Charge and discharge times are given by the following formulas:
TC=0.55RtCt
TD=RtCtLn[(0.0063Rt-2.7)/(0.0063Rt-4)]
Frequency =( TC+ TD)-1
Oscillator simplified circuit.
1
2
3
4
8
7
6
5
COMP
FB
Vref
Vcc
Rt
Ct
Isense
R/C
OUT
GND
© Copyright 2010- ASIC Advantage, Inc.
–
AADS00012 / R127B
-
Preliminary
-
October 2010 4 / 8