Rotary Switches
AC 09, 16 and 32
Insertion example 1
AC09-C २ 0/7L1 २
➀ Step angle
X: 30°, W: 360°/13,
Y: 15°, Z: 360°/26
➃ With a stopper screw
Blank: With stopper screw
E: No stopper screw
➁ Start position setting: 0
➂ End position setting: 7
• If symbol ➀ (step angle) is X-----type AC09-CX0/7L1:
Insert the start side stopper screw in hole A and the end side screw in hole Q.
Start position setting
End position setting
Range of switch action
Setting
0
1
2
3
4
5
6
7
8
9
10 11
Stopper screw
position
C
E
G
I
M
O
Q
S
U
W
A
A
K
End side stopper screw position
Start side stopper screw
position
04
• If symbol ➀ (step angle) is W-----type AC09-CW0/7L1:
Insert the start side stopper screw in hole A and the end side screw in hole Q.
Start position setting
End position setting
Range of switch action
Setting
0
1
2
3
4
5
6
7
8
9
10 11 12
Stopper screw
position
C
E
G
I
M
O
Q
S
U
W
Y
A
A
K
End side stopper screw position
Start side stopper screw
position
• If symbol ➀ (step angle) is Y-----type AC09-CY0/7L1:
Insert the start side stopper screw in hole A and the end side screw in hole J.
Start position setting
Range of switch action
End position setting
Setting
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Start side
End side
Stopper screw
position
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
A
B
End side stopper screw position
Start side stopper
screw position
Notes: 1. If the range of action is designated as 0/22 (0 to 22), insert a stopper screw into hole A only.
2. If the range of action is designated as 0/23 (0 to 23), no stopper screws are inserted (symbol
is E).
➃
• If symbol ➀ (step angle) is Z-----type AC09-CZ0/7L1:
Insert the start side stopper screw in hole A and the end side screw in hole J.
Start position setting
Range of switch action
End position setting
Setting
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
Start side
End side
Stopper screw
position
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
A
B
End side stopper screw position
Start side stopper
screw position
Notes: 1. If the range of action is designated as 0/24 (0 to 24), insert a stopper screw in hole A only.
2. If the range of action is designated as 0/25 (0 to 25), no stopper screws are inserted (symbol
is E).
➃
Insertion example 2
AC09-RX2/11
Step angle
End position setting
Start position setting
Start position setting
End position setting
Range of switch action
Setting
0
1
2
3
4
5
6
7
8
9
10 11
Stopper screw position
C
E
G
I
M
O
Q
S
U
W
A
A
K
End side stopper screw position
Start side stopper screw position
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
04/213
Information subject to change without notice