AAT2820
Triple-Output Charge Pump Regulator
Electrical Characteristics1
VIN = 3.3V; CIN = COUT = CFLY = 1.0µF, TA = 0°C to +85°C, unless otherwise noted.
Typical values are TA = 25°C.
Symbol Description
Conditions
Min Typ Max Units
VIN
Input Supply Range
2.7
5.5
V
Input Under-Voltage Lockout
Threshold
V
IN Rising
VIN Falling
FBP = 1.5V, VFBN = -0.2V, No Load on
1.8
1.6
UVLO
V
V
ICC
Operating Current
DRVN and DRVP; EN = EN/PN = VIN
VEN = VEN/PN = 0V
5.0
mA
µA
ISD
TSS
Shutdown Supply Current
Soft-Start Time
0.1 1.0
200
µs
FOSC
Operating Frequency
1.0
MHz
Negative Low-Power Charge Pump
VFBN
IFBN
FBN Regulation Voltage
-100
-100
0
+100 mV
FBN Input Bias Current
Maximum Negative Output Current2 3.3 ≤ VIN ≤ 5.5; No Load at VPOS and VOUT
VFBN = -50mV
+100
25
nA
mA
Ω
INEG
RDS_NCH DRVN NCH On-Resistance
1.5 5.0
1.0 5.0
20
MIN DRVN PCH On-Resistance
RDS_PCH
VFBN = 100mV, VIN = 4V
VFBN = -100mV, VIN = 4V
Ω
kΩ
MAX DRVN PCH On-Resistance
Positive Low-Power Charge Pump
VFBP
IFBP
FBP Regulation Voltage
1.15 1.2 1.25
V
nA
mA
Ω
FBP Input Bias Current
Maximum Positive Output Current2 3.3 ≤ VIN ≤ 5.5; No Load at VNEG and VOUT
DRVP PCH On-Resistance
VFBP = 1.5V
-60
+100
25
IPOS
RDS_PCH
1.0 5.0
MIN DRVP NCH On-Resistance
MAX DRVP NCH On-Resistance
VFBP = 1.15V, VIN = 4V
VFBP = 1.25V, VIN = 4V
3
15
Ω
kΩ
RDS_NCH
20
Reference
Reference Voltage
-2.0µA < IREF < 50µA
VREF Rising
1.18 1.2 1.22
0.8
VREF
Reference Under-Voltage Lockout
Threshold
V
VEN(L)
VEN(H)
II
EN and EN/PN Threshold Low
EN and EN/PN Threshold High
Enable Input Current
Over-Temperature Shutdown
Threshold
0.5
1.0
V
V
1.5
-1.0
µA
°C
TSD
140
15
THYS
Over-Temperature Shutdown
Hysteresis
°C
Regulated 5V Charge Pump
Output Voltage Tolerance
2.7V < VIN < 5V, IOUT = 50mA
±4.0
%
V
VOUT
Output Voltage
3.0V < VIN < 5V, IOUT = 100mA
4.8 5.0 5.2
150
IOUT
Maximum Output Current2
3.3 ≤ VIN ≤ 5.5; No Load at VPOS and VNEG
mA
1. The AAT2820 is guaranteed to meet performance specifications from 0°C to 70°C. Specification over the -40°C to +85°C operating
temperature range is assured by design, characterization, and correlation with statistical process controls.
2. Loads greater than those listed in maximum output load conditions may cause permanent damage to the device.
4
2820.2006.04.1.4