Panel Mount
Datasheet
MECHANICAL SPECIFICATIONS (4)
Tolerances: 0.02 ꢀn ꢁ 0.5 ꢂꢂ
All dꢀꢂensꢀons are ꢀn: ꢀnches [ꢂꢀllꢀꢂeters]
(2)
Screw Termination
Hex Standoff Termination (“K” Option)
1.1
1.1
Mounting
0.89
[22.6]
[27.9]
1.04
[26.4]
[27.9]
Hole/Slot
0.19 [4.9]
DIA.
Mounting
0.49
[12.4]
0.49
[12.4]
Hole/Slot
0.19 [4.9]
DIA.
2
1
OUTPUT
2
1
OUTPUT
S O L I D S TAT E R E L AY
2.25
[57.3]
1.70
[43.2]
1.88
[47.6]
S O L I D S TAT E R E L AY
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
4
INPUT
3
4
INPUT
3
0.93
[23.6]
1.0
1.0
[25.4]
[25.4]
(4 places)
1.75
[44.5]
1.75
[44.5]
1.0
[25.4]
(2 places)
Quick Connect Termination (“F” Option) - Up to 25 Amp (1)
Quick Connect Termination (“F” Option) - Up to 50 Amp (1)
Faston Terminal(13)
0.25 x 0.032
1.58
1.58
[40.2]
0.63
1.31
[33.4]
1.31
[33.4]
Faston Terminal(13)
0.25 x 0.032
[40.2]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
Mounting
Hole/Slot
0.19 [4.9]
DIA.
(4 places)
0.49
[12.4]
(2 places)
[16.0]
0.45
[11.4]
(2 places)
2
1
OUTPUT
2
1
OUTPUT
S O L I D S TAT E R E L AY
S O L I D S TAT E R E L AY
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
4
INPUT
3
4
INPUT
3
0.49
1.40
Faston Terminal(13)
0.187 x 0.020
[12.4]
[35.6]
Faston Terminal(13)
0.187 x 0.020
1.40
[35.6]
1.75
1.25
[31.8]
1.75
[44.5]
1.25
[31.8]
(2 places)
(2 places)
[44.5]
GENERAL NOTES
(1) Single pair (up to 25 A) Double pair* (50 A model only). *Caution: User must connect to both pairs.
(2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps.
For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support.
(3) Instantaneous turn-on not recomended for capacitive loads. Use zero turn-on only.
(4) All parameters at 25°C unless otherwise specified.
(5) For “S” option, operating voltage frequency is 47-63Hz.
(6) For parts with option “S” maximum leakage current is 10mA.
(7) Heat sinking required, see derating curves.
(8) Increase minimum voltage by 1V for operations from -20 to -40°C.
(9) Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models).
(10) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(11) Load can be wired to either SSR output terminal 1 or 2.
(12) Elective Internal Snubber, “S” option.
(13) Mechanical dimensions vary from G3 models.
For additional information or specific questions, contact Crydom Technical Support.
Do not forget to visit us at: www.crydom.com