3972
DUAL DMOS FULL-BRIDGE
MICROSTEPPING PWM MOTOR DRIVER
FUNCTIONAL DESCRIPTION (continued)
Word 1 Bit Assignments
For example, with a master oscillator frequency of 4 MHz, the
fast-decay time will be adjustable from 1.75 µs to 63.75 µs in
increments of 2 µs.
Bit
Function
D0
D1
D2
D3
Word select = 1
Blank-time LSB
Blank-time MSB
Off-time LSB
D8 – D11 Fast Decay Time. These four bits set the fast-
decay portion of fixed off-time for the internal PWM control
circuitry. The fast-decay portion is defined by:
D4
Off-time bit 1
tfd = [(1 + N) x 8/fOSC] - 1/fOSC
D5
D6
Off-time bit 2
Off-time bit 3
where N = 0….15
For example, with an oscillator frequency of 4 MHz, the fast-
decay time will be adjustable from 1.75 µs to 31.75 µs in
increments of 2 µs. For tfd > toff , the device will effectively
operate in fast-decay mode.
D7
D8
D9
Off-time MSB
Fast-decay time LSB
Fast-decay time bit 1
Fast-decay time bit 2
Fast-decay time MSB
C0 oscillator control
C1 oscillator control
SR control bit 1
SR control bit 2
Reserved for testing
Reserved for testing
Idle mode
D10
D11
D12
D13
D14
D15
D16
D17
D18
D12 – D13 Oscillator Control. A 4 MHz internal oscillator
is used for the timing functions and charge-pump clock. If
more precise control is required, an external oscillator can be
input to the OSC terminal. To accommodate a wider range of
system clocks, an internal divider is provided to generate the
desired MO frequency according to the following table:
D13
D12
OSC
0
0
1
1
0
1
0
1
4 MHz internal clock
External clock
External clock/2
External clock/4
D1 – D2 Blank Time. These two bits set the blank time for
the current-sense comparator. When a source driver turns on, a
current spike occurs due to the reverse-recovery currents of the
clamp diodes and/or switching transients related to distributed
capacitance in the load. To prevent this current spike from
erroneously resetting the source-enable latch, the sense com-
parator is blanked. The blank timer runs after the off-time
counter to provide the programmable blanking function. The
blank timer is reset when PHASE is changed.
D14 – D15 Synchronous Rectification.
D15
D14
Synchronous Rectifier
0
0
1
1
0
1
0
1
Active
Disabled
Passive
Low side only
D2
D1
Time
The different modes of operation are in the synchronous
rectification section of the functional description.
0
0
1
0
1
0
4/fOSC
6/fOSC
8/fOSC
D16, D17. These bits are reserved for testing and should be
1
1
12/fOSC
programmed to zero during normal operation.
D18 Idle Mode. The device can be placed in a low power
“idle” mode by writing a “0” to D18. The outputs will be
disabled, the charge pump will be turned off, and the device
will draw a lower load supply currrent. The undervoltage
monitor circuit will remain active. D18 should be programmed
high for 1 ms before attempting to enable any output driver.
D3 – D7 Fixed Off Time. These five bits set the fixed off-
time for the internal PWM control circuitry. Fixed off-time is
defined by:
toff = [(1 + N) x 8/fOSC] - 1/fOSC
where N = 0….31
continued next page ...