3134
LOW-HYSTERESIS
BIPOLAR HALL-EFFECT SWITCH
FOR HIGH-TEMP. OPERATION
FUNCTIONAL BLOCK DIAGRAM
1
V
CC
REG.
3
2
OUTPUT
GROUND
X
Dwg. FH-005-3
ELECTRICAL CHARACTERISTICS over operating temperature range, at VCC = 12 V.
Limits
Characteristic
Symbol
VCC
Test Conditions
Operating
Min.
4.5
—
Typ.
—
Max.
24
Units
V
Supply Voltage
Output Saturation Voltage
Output Leakage Current
Supply Current
VOUT(SAT)
IOFF
IOUT = 20 mA, B > BOP
VOUT = 24 V, B < BRP
175
0.05
400
1.0
mV
µA
—
ICC
B < BRP
B > BOP
(Output
(Output
OFF)
ON)
—
3.2
5.0—
9.0mA
mA
—
Output Rise Time
Output Fall Time
tr
tf
RL = 820 Ω, CL = 20 pF
RL = 820 Ω, CL = 20 pF
—
100
100
—
—
ns
ns
—
MAGNETIC CHARACTERISTICS over oper. temp. and oper. supply voltage ranges.
Limits
Characteristic
Operate Point
Release Point
Hysteresis
Symbol
BOP
Test Conditions
Min.
Typ.
Max.
Units
-408.5
-50-19
5.027
60 G
BRP
50 G
55
Bhys
G
NOTES: BOP = operate point (output turns ON); BRP = release point (output turns OFF); Bhys = hysteresis (BOP - BRP).
As used here, negative flux densities are defined as less than zero (algebraic convention).
Typical values are at TA = +25°C and VCC = 12 V.
1 gauss (G) is exactly equal to 0.1 millitesla (mT).
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
Copyright © 1995, 2003 Allegro MicroSystems, Inc.