AC axial fans
A-Range, Ø 250
-
-
Material: sheet steel (coated in black)
Direction of rotation: direction of air flow "V" counter-clockwise,
direction of air flow "A" clockwise
-
Type of protection: IP 44
ebm-papst · Mulfingen
Nominal data
Type
3
-1
Motor
VAC
Hz
m /h
min
W
A
µF/VDB dB(A)
Pa
°C
kg
230/400 50
230/400 60
1685
1845
1610
1740
890
1035
2650
2950
2550
2750
1420
1650
1400
1620
110
160
115
165
30
35
72
67
0,22
0,26
0,51 4,0/400
0,74 4,0/400
0,09
0,08
0,53
0,46
---
---
72
75
72
73
58
62
58
62
300
300
150
130
90
100
70
40
55
50
75
75
40
50
(1)
1
2
3
4
*2D 250
M2D068-DF
M2E068-DF
M4D068-CF
M4S068-CF
2,2
2,2
1,6
1,7
230
230
50
60
*2E 250
230/400 50
230/400 60
---
---
---
---
(1)
*4D 250
230
230
50
60
870
1000
80
100
*4S 250
subject to alterations
(1) current draw established at 400 VAC (Y)
n
P1
[W]
n
P1
[W]
[min-1]
[min-1]
1
1
2
2
1
2
1
2
3
3
4
4
1
2645
2615
2520
2480
123
131
122
126
1420
1410
1400
1395
32
33
70
71
2
1
2
Characteristics
Characteristics
100
80
60
40
20
300
200
100
3
1
2
2
2
2
4
1
1
1
0
250
500
750
1000 [CFM]
[m3/h]
60 Hz
0
200
400
600 [CFM]
400
800
1200
1600
200
400
600
800
1000 [m3/h]
50 Hz
50 Hz
60 Hz
62