Panel Mount
DataSheet
MECHANICAL SPECIFICATIONS (1)
Tolerances: 0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
(12)
Screw Termination
Hex Standoff Termination (“K” Option)
1.1
1.1
Mounting
0.89
[22.6]
[27.9]
1.04
[26.4]
[27.9]
Hole/Slot
0.19 [4.9]
DIA.
Mounting
0.49
[12.4]
0.49
[12.4]
Hole/Slot
0.19 [4.9]
DIA.
2
1
OUTPUT
2
1
OUTPUT
S O L I D S TAT E R E L AY
2.25
[57.3]
1.70
[43.2]
1.88
[47.6]
S O L I D S TAT E R E L AY
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
4
INPUT
3
4
INPUT
3
0.93
[23.6]
1.0
1.0
[25.4]
[25.4]
(4 places)
1.75
[44.5]
1.75
[44.5]
1.0
[25.4]
(2 places)
Quick Connect Termination (“F” Option) - Up to 25 Amp (5)
Quick Connect Termination (“F” Option) - Up to 50 Amp (5)
Faston Terminal(14)
0.25 x 0.032
1.58
1.1
1.31
[33.4]
1.31
[33.4]
Faston Terminal(14)
0.25 x 0.032
[40.2]
[27.9]
0.63
Mounting
Hole/Slot
0.19 [4.9]
DIA.
Mounting
Hole/Slot
0.19 [4.9]
DIA.
(4 places)
0.49
[12.4]
(2 places)
[16.0]
0.45
[11.4]
(2 places)
2
1
OUTPUT
2
1
OUTPUT
S O L I D S TAT E R E L AY
S O L I D S TAT E R E L AY
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
4
INPUT
3
4
INPUT
3
0.49
1.40
Faston Terminal(14)
0.187 x 0.020
[12.4]
[35.6]
Faston Terminal(14)
0.187 x 0.020
1.40
[35.6]
1.75
1.25
[31.8]
1.75
[44.5]
1.25
[31.8]
(2 places)
(2 places)
[44.5]
GENERAL NOTES
(1) All parameters at 25°C unless otherwise specified.
(2) Heat sinking required, see derating curves. For “K” option maximum current up to 50 Amp.
(3) For relays with option “G” minimum control voltage is 4.5VDC.
(4) Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models).
(5) Single pair (up to 25A) Double pair* (50A model only). *Caution: User must connect to both pairs.
(6) Output will self trigger between 450-600Vpk, not suitable for capacitive loads.
(7) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only.
(8) For 40mA minimum current, the voltage drop increases over maximum rated.
(9) Elective Input Status LED, “G” option.
(10) Elective Overvoltage Protection, “P” option.
(11) Load can be wired to either SSR output terminal 1 or 2.
(12) Option “K” is intended only for use in attaching a printed circuit board to the SSR or mounting the SSR to a printed circuit board (PCB minimum thickness is 0.031 in)
(13) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(14) Mechanical dimensions vary fro m G3 models.
For additional information or specific questions, contact Crydom Technical Support.
Do not forget to visit us at: www.crydom.com
Copyright © 2014 Crydom Inc. Specifications subject to change without notice.