A1242
Two-Wire Chopper-Stabilized Hall Effect Latch
ELECTRICAL CHARACTERISTICS over full operating voltage and temperature ranges, unless otherwise specified
1
Characteristic
Symbol
Test Conditions
Min.
Max.
Units
Typ.
Electrical Characteristics
2 3
VCC
Operating, TJ < 165°C
3.5
5
–
–
24
6.9
5
V
mA
mA
mA
mA/μs
kHz
μs
Supply Voltage
-I1, B < BRP
ICC(L)
Supply Current
-I2, B < BRP
2
–
ICC(H)
dI/dt
-I1 and -I2, B > BOP
12
–
–
17
–
4
RS = 100 Ω, CS = 20 pF, no bypass capacitor
36
200
–
Output Slew Rate
Chopping Frequency
Power-On Time
fC
–
–
tPO
VCC > VCC(MIN)
–
25
–
5
POS
VZ(supply)
IZ(supply)
IRCC
tPO < tPO(max), dVCC/dt > 25 mV/μs
ICC = 20 mA; TA = 25°C
VS = 28 V
–
ICC(H)
–
–
Power-On State
Supply Zener Clamp Voltage
28
–
–
V
6
–
20
2.5
mA
mA
Supply Zener Current
Reverse Battery Current
VRCC = –18 V
–
–
7
Magnetic Characteristics
Operate Point
Release Point
Hysteresis
BOP
BRP
South pole adjacent to branded face of device
North pole adjacent to branded face of device
BOP – BRP
5
32
–32
64
80
–5
G
G
G
–80
40
BHYS
110
1 Typical values are at TA = 25°C and VCC = 12 V. Performance may vary for individual units, within the specified maximum and minimum
limits.
2 Maximum voltage must be adjusted for power dissipation and junction temperature; see Power Derating section.
3 VCC represents the generated voltage between the VCC pin and the GND pin.
4 The value of dI is the difference between 90% of ICC(H) and 10% of ICC(L), and the value of dt is time period between those two points.
The value of dI/dt depends on the value of the bypass capacitor, if one is used, with greater capacitances resulting in lower rates of
change.
5 For t > tPO(max), and BRP < B < BOP, POS is undefined.
6 Maximum current limit is equal to the maximum ICCL(max) + 3 mA.
7
Magnetic flux density, B, is indicated as a negative value for north-polarity magnetic fields, and as a positive value for south-polarity
magnetic fields. This so-called algebraic convention supports arithmetic comparison of north and south polarity values, where the relative
strength of the field is indicated by the absolute value of B, and the sign indicates the polarity of the field (for example, a –100 G field and
a 100 G field have equivalent strength, but opposite polarity).
DEVICE QUALIFICATION PROGRAM
Contact Allegro for information.
EMC (Electromagnetic Compatibility) PERFORMANCE
Contact Allegro for information.
Allegro MicroSystems, Inc.
3
115 Northeast Cutoff, Box 15036
A1242-DS
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com