Engineering Data
■ Mechanical Durability (A-20G)
■ Electrical Durability (A-20G)
1,000
1,000
Ambient temperature: 20
2°C
Ambient temperature: 20
2°C
700
500
700
Ambient humidity: 65 5%RH
Without load
Operating frequency:
240 operations/min
Ambient humidity: 65 5%RH
Operating frequency:
20 operations/min
500
300
300
125 VAC, cosφ = 1
125 VAC,
cosφ = 0.4
250 VAC,
cosφ = 1
100
100
70
50
70
50
250 VAC, cosφ = 0.4
30
30
10
10
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7 0.8
0
5
10
15
20
25
Overtravel (mm)
Switching current (A)
■ Structure
Contact Form (SPDT)
COM
NC
NO
Dimensions
Note: Unless otherwise specified, all units are in millimeters and a tolerance of ± 0.4 mm applies to all dimensions.
■ Terminals
Screw Terminals (-B)
Solder Terminal (Blank)
9.2
6.4
25.4 0.1
3
11.9
17.45 0.2
20
20
17.45 0.2
1
NO
COM
NC
COM
1
NO
NC
2
2
3
Three, M4 × 5.5
Terminal screws
(with toothed washer)
49.2
49.2
Note: Appropriate terminal screw tightening torque: 0.78 to 1.18 N·m.
■ Mounting Holes
All switches can be mounted using M4 mounting screws with plane
washers or spring washers to securely mount the Switch. Tighten the
screws to a torque of 1.18 to 1.47 N·m.
Versions with panel mount plungers can be panel mounted via the
plunger, provided that the hexagonal nut of the actuator is tightened
to a torque of 2.94 to 4.9 N·m.
Two, 4.2 dia. mounting
holes or M4
Panel Mount Plunger
Panel Mount Roller Plunger
12.5+0.2dia.
12.5+0.2dia.
0
0
25.4 0.1
5+
0.2
0
13+
0.2
0
Note: Mount using either the side mounting holes or the panel mount plunger, not both. If using the side mounting holes, then remove the hexagonal nut(s)
from the panel mount plunger.
Accessories (Terminal Covers, and Separators): Refer to ‘Z/A/X/DZ Common Accessories’ datasheet
Snap Action Switch A
21