● EN 60950 certified, rated for 250VAC
● UL-60950-1 / CSA C22.2 certified
● 5.2kVDC Isolation for 1 Minute
● Optional Continuous Short Circuit Protected
● Wide Temperature Performance at
full 1 Watt Load, –40°C to +85°C
● 2 Chamber Transformer System
● UL94V-0 Package Material
ECONOLINE
Features
DC/DC-Converter
Unregulated
Converters
RxxPxxS_D
Series
● Efficiency to 80%
Selection Guide
1 Watt
Part
Number
Input
Voltage
Output
Voltage
Output
Current
Efficiency
SIP 7
Single & Dual
Output
SIP 7
(VDC)
(VDC)
3.3
5
(mA)
303
200
111
84
(%)
70
RxxP3.3S
RxxP05S
RxxP09S
RxxP12S
RxxP15S
RxxP3.3D
RxxP05D
RxxP09D
RxxP12D
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
70-75
70-75
70-75
75-80
70
9
12
15
3.3
5
66
151
100
55
70-75
70-75
70-75
75-80
9
12
15
41
RxxP15D
33
xx = Input Voltage
* add Suffix “P” for Continuous Short Circuit Protection, e.g. R05P05S/P, R05P05D/P
EN-60950-1 Certified
UL-60950-1 Certified
EN-60601-1 Certified
Description
The RxxPxxS_D Series of DC/DC Converters are fully certified to EN 60950/ UL-60950-1 and CSA C22.2.
This makes them ideal for all telecom and safety applications where approved isolation is required.
Specifications
(measured at T = 25°C, at nominal input voltage and rated output current unless otherwise specified)
A
Input Voltage Range
10%
5%
Output Voltage Accuracy
Line Voltage Regulation
1.2%/1% of Vin typ.
Load Voltage Regulation
(10% to 100% full load)
3.3, 5V output types
other output types
15% max.
10% max.
Derating-Graph
(Ambient Temperature)
Output Ripple and Noise (20MHz BW)
Operating Frequency
200mVp-p max.
20kHz min. / 50kHz typ. / 85kHz max.
65% min. / 75% typ.
Efficiency at Full Load
No Load Power Consumption
148mW min. / 220mW typ. / 355mW max.
100
80
Isolation Voltage
Rated Working Voltage
(tested for 1 minute)
(long term isolation)
5200VDC min.
see Application Notes
Isolation Capacitance
Isolation Resistance
4pF min. / 10pF max.
60
Safe Operating Area
15 GΩ min.
40
30
20
Short Circuit Protection
P-Suffix
1 Second
Continuous
0
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
-40°C to +85°C (see Graph)
-55°C to +125°C
95% RH
-40
0
50
100 150
85
Operating Temperature °C
Package Weight
4.3g
MTBF (+25°C)
using MIL-HDBK 217F
using MIL-HDBK 217F
2974 x 103 hours
728 x 103 hours
Detailed Information see
Application Notes chapter "MTBF"
}
(+85°C)
July-2006
44