Cyclone V Device Datasheet
2015.12.04
Send Feedback
CV-51002
Subscribe
This datasheet describes the electrical characteristics, switching characteristics, configuration specifications, and I/O timing for Cyclone® V
devices.
Cyclone V devices are offered in commercial and industrial grades. Commercial devices are offered in –C6 (fastest), –C7, and –C8 speed grades.
Industrial grade devices are offered in the –I7 speed grade. Automotive devices are offered in the –A7 speed grade.
Related Information
Cyclone V Device Overview
Provides more information about the densities and packages of devices in the Cyclone V family.
Electrical Characteristics
The following sections describe the operating conditions and power consumption of Cyclone V devices.
Operating Conditions
Cyclone V devices are rated according to a set of defined parameters. To maintain the highest possible performance and reliability of the Cyclone
V devices, you must consider the operating requirements described in this section.
Absolute Maximum Ratings
This section defines the maximum operating conditions for Cyclone V devices. The values are based on experiments conducted with the devices
and theoretical modeling of breakdown and damage mechanisms.
The functional operation of the device is not implied for these conditions.
©
2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are trademarks of Altera Corporation and registered in the U.S. Patent
and Trademark Office and in other countries. All other words and logos identified as trademarks or service marks are the property of their respective holders as described at www.altera.com/common/legal.html. Altera
warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without
notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are
advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services.