General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR6 A/B/C/V (Continued)
Insulation Data
Other Data
Initial dielectric strength
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
between open contacts
between contact and coil
between adjacent contacts
Clearance/creepage
between open contacts
between contact and coil
between adjacent contacts
Insulation to EN 50178, type of insulation
between contact and coil
between adjacent contacts
1500Vrms
4000Vrms
3000Vrms
www.te.com/customersupport/rohssupportcenter
Ambient temperature
Category of environmental Protection
IEC 61 810
-25 to 70°C
microdisconnection
≥5.5/5.5mm
RTIII
30g
Weight
≥5.5/5.5mm
Resistance to soldering heat THT
IEC 60068-2-20
Packaging/unit
260°C/5s
tube/10 pcs.
reinforced
reinforced
For more detailed information see product specification 2158003
Accessories
27E1079
27E1081
24A243
SR6A and SR6B socket (1423991-1)
SR6C socket (1423992-1)
Relay hold down clip (1423994-1)
For details see datasheet 1654787
Dimensions
SR6 A/B/C
SR6 V
S0367-DN
S0367-DU
PCB layout / terminal assignment
Bottom view
3 form A + 3 form B, 3 NO + 3 NC versions
SR6 A
4 form A + 2 form B, 4 NO + 2 NC versions
SR6 B
5 form A + 1 form B, 5 NO + 1 NC versions
SR6 C
S0368-CA
S0368-CA
S0368-CE
S0368-CC
S0368-CB
S0368-CD
4 form A + 2 form B, 4 NO + 2 NC versions
SR6 V
The design of the SR6 V allows
clearance/creepage of 5.5 mm
on the PCB.
S0368-CU
S0368-CV
2
11-2012, Rev. 1112
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company