786 Series  
General Purpose Pulse Transformers  
TUBE OUTLINE DIMENSIONS  
TECHNICAL NOTES  
ISOLATION VOLTAGE  
10.95  
(0.43)  
REPEATED HIGH-VOLTAGE  
ISOLATION TESTING  
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Volt-  
age’, ‘Proof Voltage’, ‘Dielectric Withstand  
It is well known that repeated high-voltage  
4.00 (0.16)  
Voltage’ & ‘Isolation Test Voltage’ are all terms isolation testing of a barrier component can  
that relate to the same thing, a test voltage,  
applied for a specified time, across a compo-  
actually degrade isolation capability, to a  
lesser or greater degree depending on ma-  
0.60 0.15  
(0.023 0.005)  
12.95  
(0.51)  
nent designed to provide electrical isolation, to terials, construction and environment. This  
5.50 (0.22)  
verify the integrity of that isolation.  
series has toroidal isolation transformers,  
with no additional insulation between pri-  
mary and secondary windings of enameled  
wire. While parts can be expected to with-  
stand several times the stated test voltage,  
the isolation capability does depend on the  
wire insulation. Any material, including this  
enamel (typically polyurethane) is suscep-  
tible to eventual chemical degradation when  
subject to very high applied voltages thus  
implying that the number of tests should be  
strictly limited. We therefore strongly advise  
against repeated high voltage isolation test-  
ing, but if it is absolutely required, that the  
voltage be reduced by 20ꢀ from specified  
test voltage.  
All products in this series are 100ꢀ production  
tested at their stated isolation voltage.  
3.80  
(0.15)  
15.70 (0.62)  
A question commonly asked is, “What is the  
continuous voltage that can be applied across  
the part in normal operation?”  
Tube length: 465 2 (18.3 0.08). Tube quantity: 50.  
Tube material: Antistatic coated clear pvc.  
Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01).  
For a part holding no specific agency approv-  
als both input and output should normally be  
maintained within SELV limits i.e. less than  
42.4V peak, or 60VDC. The isolation test  
voltage represents a measure of immunity to  
transient voltages and the part should never  
be used as an element of a safety isolation  
system. The part could be expected to function  
correctly with several hundred volts offset  
applied continuously across the isolation bar-  
rier; but then the circuitry on both sides of the  
barrier must be regarded as operating at an  
unsafe voltage and further isolation/insulation  
systems must form a barrier between these  
circuits and any user-accessible circuitry ac-  
cording to safety standard requirements.  
This consideration equally applies to agency  
recognized parts rated for better than  
functional isolation where the wire enamel  
insulation is always supplemented by a  
further insulation system of physical spacing  
or barriers.  
USA:  
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com  
UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Mansfield (MA), Tel: (800) 233 2765, email: sales@murata-ps.com  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED  
France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com  
Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
Website: www.murata-ps.jp  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KMP_786C_B02 Page 4 of 4  

与78604/1MC相关器件

型号 品牌 描述 获取价格 数据表
78604/1M-R MURATA Pulse Transformer, GENERAL PURPOSE Application(s), 2:1, CHIP

获取价格

78604/2 MURATA Pulse Transformer, GENERAL PURPOSE Application(s), 2:1

获取价格

78604/2C MURATA General Purpose Pulse Transformers

获取价格

78604/2JC Surface Mount General Purpose Pulse Transformers

获取价格

78604/2JC MURATA 民用设备,工业设备

获取价格

78604/2JC-R MURATA Pulse Transformer, GENERAL PURPOSE Application(s), 2:1, ROHS COMPLIANT

获取价格