Portable, Modular Signal Conditioning Modules  
Overvoltage protection ....................... ±28 Vp (powered on or off)  
Input impedance ................................. 10 MΩ powered on, 10 kΩ  
powered off or overload  
Gain error ............................................ ±0.8ꢀ of reading maximum  
Offset error.......................................... ±5 µV  
NI SCC-SG Series Strain Gage  
Input/Excitation  
Bandwidth........................................... 1.± kHz (single-pole RC filter)  
Excitation voltage ............................... 2.5 V ±0.4ꢀ  
Excitation Current Drive  
SG01, SG02......................................... 42 mA (with 2 120 Ω gages)  
SG03, SG04......................................... ±0 mA (with 2 350 Ω gages)  
Excitation drift..................................... 13 mV/°C  
Power Requirements  
Model  
Channel  
Description  
Part Number  
777459-13  
777459-14  
777459-15  
777459-1±  
777459-17  
777459-37  
Analog................................................. 143 mW  
Digital.................................................. 210 mW  
SCC-SG01  
SCC-SG02  
SCC-SG03  
SCC-SG04  
SCC-SG11  
SCC-SG24  
2
2
2
2
2
2
120 Ω, quarter-bridge strain gages  
350 Ω, quarter-bridge strain gages  
Half-bridge strain gages  
Full-bridge strain gages  
Shunt calibration  
Full-bridge strain gages, load cells,  
pressure sensors, torque sensors  
SCC-SG11  
Number of channels............................  
2
Control signal...................................... 1 DIO channel  
Resistor for each channel................... 301 kΩ ±1ꢀ, socketed  
Resistor temperature coefficient........ ±100 ppm/°C  
The National Instruments SCC-SG Series consists of dual-channel strain  
gage modules for conditioning quarter, half, and full-bridge strain gages  
and a calibration module. Each module is designed for a specific type of  
bridge configuration. Each channel of an NI SCC-SG module (except  
SCC-SG11) includes an instrumentation amplifier, a 1.± kHz lowpass  
filter, and a potentiometer for bridge-offset nulling. Each SCC-SG0x  
module also includes a single 2.5 V excitation source. The SCC-SG24  
has a 10 V excitation source for load cells and pressure sensors.  
The SCC-SG11 is a dual-channel shunt calibration module for use with  
the SCC-SG0x and SCC-SG24 modules. Each channel includes two  
terminals for wiring a switched 301 kΩ, 1 percent, 1⁄4 W resistor across  
any two points of your bridge. You enable shunt calibration for both  
channels of a module by writing a logic high to the digital line controlling  
the SCC-SG11. You disable shunt calibration by writing a logic low to the  
same digital line.  
Power Requirements  
Digital.................................................. 25 µW  
SCC-SG24  
Input Characteristics  
Number of channels............................ 2 differential  
Input signal range............................... ±100 mV  
Output signal range ............................ ±10 V  
Gain .................................................... 100  
Overvoltage protection ....................... ±42 VDC powered on and  
powered off  
Input impedance ................................. 20 MΩ powered on >±0 kΩ  
powered off or overload  
Gain error ............................................ ±0.20ꢀ of reading max  
Offset error.......................................... ±50 µV typ, 325 µV max before  
calibration1  
Bandwidth........................................... 1.± kHz single-pole buffered RC  
filter  
Excitation voltage ............................... 10 V ±0.05ꢀ  
Excitation current drive....................... ±0 mA, based on two full-bridge  
350 Ω strain gages  
When you install an SCC-SG module in the SC-2345, the carrier routes  
the strain gage signals to two input channels of the multifunction DAQ  
device, channels x and x+8, where x is 0 through 7.  
Specifications  
SCC-SG0x  
Excitation drift..................................... 10 ppm/°C  
Power Requirements  
Analog................................................. 340 mW  
Digital.................................................. 930 mW  
Input Characteristics  
Number of channels............................ 2 differential  
Input signal range............................... ±100 mV  
Output signal range ............................ ±10 V  
Gain .................................................... 100  
1By factory default, the nulling resistors are not installed in the SCC-SG24. See the user  
manual for information on installing the nulling resistors.  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
6

与777459-28相关器件

型号 品牌 描述 获取价格 数据表
777459-32 NI SCC Configuration Guide

获取价格

777459-33 NI SCC Configuration Guide

获取价格

777459-34 NI SCC Configuration Guide

获取价格

777459-37 NI SCC Configuration Guide

获取价格

777459-50 NI SCC Configuration Guide

获取价格

77747-301 AMPHENOL Wire Terminal

获取价格