SN74AUP1G126
SCES596F –JULY 2004–REVISED MAY 2010
www.ti.com
ABSOLUTE MAXIMUM RATINGS(1)
over operating free-air temperature range (unless otherwise noted)
MIN
–0.5
–0.5
–0.5
MAX UNIT
VCC
VI
Supply voltage range
Input voltage range(2)
Voltage range applied to any output in the high-impedance or power-off state(2)
Output voltage range in the high or low state(2)
4.6
4.6
4.6
V
V
VO
VO
IIK
V
–0.5 VCC + 0.5
V
Input clamp current
VI < 0
–50
–50
±20
±50
206
252
142
TBD
234
132
mA
mA
mA
mA
IOK
IO
Output clamp current
VO < 0
Continuous output current
Continuous current through VCC or GND
DBV package
DCK package
DRL package
qJA
Package thermal impedance(3)
°C/W
°C
DSF package
DRY package
YFP/YZP/YZT package
Tstg
Storage temperature range
–65
150
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
4
Submit Documentation Feedback
Copyright © 2004–2010, Texas Instruments Incorporated
Product Folder Link(s): SN74AUP1G126