DF80 Series■0.5mm Pitch Vertical Mating Connectors for Thin Wire Coaxial Cable
BOperating Precautions
Operating Precautions
■Connector mating procedure
• When inserting the plug, press straight down on the entire surface of the plug until it is completely inserted.
• Do not press down on the wires when mating. Inserting the plug while pressing down on the wires may cause an
angled insertion to occur and may result in damage to the connector.
■Connector unmating procedure
• Un-mating the connector can be done in two different methods : unmating with fingers or with the pull tab.
• Do not pull/hold on the terminal wires during extraction. Doing so can lead to damaged or disconnected wires.
【Unmating with fingers】
Pull up on the extension hook that is part of the connectors plug.
Extension hook
•
The extension hook is made of metal, so please use caution when manipulating it as it may cause damage to your nail or finger.
【Unmating with pull tab】
Pull up on the tab in the arrowed direction (vertically) to extract the plug.
■Do not mate and unmate this connector if it has not been mounted on a PCB, doing this can damage and
deform the contacts.
■Using excessive force while mating or unmating will damage the contacts or connector.
■When hand soldering, do not apply excessive amounts of flux. Doing so may promote solder wicking.
®
2-6-3,Nakagawa Chuoh,Tsuzuki-Ku,Yokohama-Shi 224-8540,JAPAN
+
+
TEL: 81-45-620-3526 Fax: 81-45-591-3726
http://www.hirose.com
http://www.hirose-connectors.com
The characteristics and the specifications contained herein are for reference purpose. Please refer to the latest customer drawings prior to use.
The contents of this catalog are current as of date of 09/2017. Contents are subject to change without notice for the purpose of improvements.
8